Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 0992-7689
    Keywords: Solar physics ; Astrophysics ; Astronomy ; Magnetic fields ; Space plasma physics ; Charged particle motion and acceleration
    Source: Springer Online Journal Archives 1860-2000
    Topics: Geosciences , Physics
    Notes: Abstract EISCAT observations of the interplanetary scintillation of a single source were made over an extended period of time, during which the orientation of the baselines between the two observing sites changed significantly. Assuming that maximum correlation between the scintillations observed at the two sites occurs when the projected baseline is parallel to the direction of plasma flow, this technique can be used to make a unique determination of the direction of the solar wind. In the past it has usually been assumed that the plasma flow is radial, but measurements of eleven sources using this technique have indicated conclusively that in at least six cases observed at mid or high heliocentric latitude there is a significant non-radial component directed in four cases towards the heliocentric equator and in two cases towards the pole.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1432-1041
    Keywords: Bupivacaine ; wound infiltration ; postoperative ; pharmacokinetics
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Summary After routine inguinal herniorrhaphy we gave 12 patients a wound infiltration regimen of bolus doses of 20 ml of 0.5% bupivacaine via a catheter within the wound and rectally administered indomethacin (100 mg). Peak venous plasma bupivacaine concentrations ranged from 0.07 mg·l−1 to 1.14mg·l−1 (mean (SD) 0.47 (0.33) mg·l−1), and occurred at between 0.25 and 2 h after the first dose. Plasma concentrations were well below the toxic threshold of 4 mg·l−1 and there was no accumulation. The regimen provided satisfactory analgesia. There were no wound infections nor signs of toxicity.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...