Library

Your search history is empty.
feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 438-442 
    ISSN: 0935-6304
    Keywords: Capillary electrochromatography ; micro-HPLC ; preparation of on-column frits ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: ---Existing methods for preparing frits in packed fused silica capillaries as used for electrochromatography and micro HPLC are not applicable to all silica based packing materials and involve a high thermal stress for both the stationary phase and the fused silica tubing including the polyimide coating. A new procedure for the production of such on-column frits under mild conditions by a sol-gel type reaction of polydimethoxysiloxane (PDMOS) is described in this paper. Reaction conditions were established for optimum mechanical stability and high permeability of the frits. Frits produced in this manner showed no noticeable effect on the overall efficiency.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 335-338 
    ISSN: 0935-6304
    Keywords: Capillary GC trace analysis of C2-C4 hydrocarbons ; signal-to-noise ratio, improvement ; post column cryogenic trapping ; thermal remobilization ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: ---A method for the improvement of signal-to-noise ratios and hence detection limits in capillary gas chromatographic trace analysis of C2-C4 hydrocarbons was developed. It is based on the post column cryogenic trapping of the separated hydrocarbons using liquid nitrogen as coolant and its fast reinjection into the detector by rapid heating of the capillary tubing used for trapping. The improved signal-to-noise ratios were applied to decrease the sample volume and/or to lower the detection limit 10 to 27 times. The concentrations of these hydrocarbons in an urban air sample determined without and with post column cryogenic trapping were in good agreement but the precision was better when applying the cryogenic trapping mode.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...