Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 35 (1993), S. 290-294 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Solid phase extraction ; Organochloride pesticides ; Water analysis
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Gas chromatography of chlorinated pesticides in water is carried out after adsorption of a 50 mL sample using a cartridge containing 100 mg CN-bonded porous silica and extraction with 500 μL pentane. The average recovery for eight organochloride pesticides at 1 ppb was 〉95%. The procedure described is simple, selective and reproducible.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 16 (1982), S. 330-335 
    ISSN: 1612-1112
    Keywords: Liquid Chromatography ; Solvophobic theory ; Solvent effect ; Graphitized carbon black
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The net solvent effect for several solute-solvent pairs has been calculated by using the solvophobic approach for describing the liquid chromatographic process. For the same solutes and solvents the net solvent effect has been experimentally measured by using graphitized carbon black columns in GC and HPLC. A comparison between the measured and calculated values made in terms of normalized free energy changes, indicates that the solvophobic theory is fairly adequate for predicting the sequence of solvent strength and provides a comprehensive explanation of the various interactions occurring in reversed-phase LC. Aγ critical discussion of the deviations of the theory from the experimental data is also presented.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 1 (1978), S. 143-148 
    ISSN: 0935-6304
    Keywords: Gas Chromatography ; Capillary glass ; Tailor-made by graphitized carbon black precoating ; Application to pesticides, terpenes, aromatic hydrocarbons, free fatty acids ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The performance of graphitized glass capillary columns obtained by precoating the inner glass walls with graphitized carbon black has been evaluated. It has been shown that according to the amount of stationary phase coated such columns can operate in gas-liquid-solid chromatography and in gas-liquid chromatography so that tailor-made columns for specific separations can be prepared. The versatility of these columns is shown in the separation of various mixtures (terpenes, pesticides, isomeric species and others) of analytical importance.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 0935-6304
    Keywords: Low and high resolution liquid chromatography ; Gas chromatography ; Capillary columns ; Alkali flame detection ; Chemical ionization mass spectrometry ; Nitro-PAHs ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: An analytical procedure is described for the fractionation of organic compounds present in environmental samples and the determination of nitro polyaromatic hydrocarbons (nitro-PAHs). Both low and high resolution liquid chromatography are employed for the prefractionation of the soluble organic fraction (SOF) extracted from particulate matter or gaseous pollutants collected on adsorption traps. High resolution gas chromatography is used to analyze four fractions containing alkanes, PAHs, nitro-PAHs, and other polar PAHs. Nitrogen-containing species are separated by GC and detected specifically using an alkali flame (NPD) detector. Flame ionization (FID) detection, GC-MS of positive ions, and negative ion chemical ionization MS of the whole fraction is used for the identification and quantitation of the various components. The composition of SOF extracted from particulate matter emitted from diesel exhausts is elucidated and a large number of nitro-PAHs identified by the combination of the various techniques.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗