Bibliothek

feed icon rss

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
  • 1
    ISSN: 0014-5793
    Schlagwort(e): Antithrombin mutant ; Carbohydrate attachment ; Heparin binding ; Thromboembolism
    Quelle: Elsevier Journal Backfiles on ScienceDirect 1907 - 2002
    Thema: Biologie , Chemie und Pharmazie , Physik
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    Digitale Medien
    Digitale Medien
    Springer
    Osteoporosis international 5 (1995), S. 377-381 
    ISSN: 1433-2965
    Schlagwort(e): Forearm scanning ; Peripheral bone mass ; Single X-ray absorptiometry
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Notizen: Abstract The aim of the present study was to evaluate a new device for measurement of forearm bone mass using the technique of single X-ray absorptiometry (SXA, DTX-100; Osteometer A/S, Rødovre, Denmark), and to compare the performance with the more traditional single photon absorptiometry (SPA, DT 100; Osteometer A/S, Rødovre, Denmark). The SPA phantom measurements showed a coefficient of variation of 0.43% and 0.42% for bone mineral content (BMC) and bone mineral density (BMD), respectively (39 months including seven source changes). The SXA precision errors were slightly lower with values of 0.30% and 0.30%, respectively. The patient measurements showed SPA coefficients of variation of 0.85% and 0.99% (BMC and BMD) and SXA coefficients of variation of 0.56% and 0.83%, respectively. The correlation between SPA and SXA values performed in 377 individuals yielded r values of 0.99 an 0.98 for BMC and BMD, respectively. The correlations between SXA measurements of the dominant and non-dominant forearm yielded anr-value of 0.95, with a slope of 0.949 (p〈0.001) and an intercept of 0.204 (p〈0.05). The non-dominant forearm thus had approximately 3% lower BMC than the dominant (the same was true for BMD). Correlations to spine and femur ranged fromr=0.48 tor=0.75. In conclusion, the new single X-ray absorptiometry forearm bone densitometer described in this paper has performance characteristics which allows it to be used both for diagnostic purposes and for the follow-up of treatment.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...