    ISSN: 1741-0444
    Keywords: Conditional entropy ; Corrected conditional entropy ; Regularity ; Synchronisation ; Co-ordination ; Complexity ; Cardiovascular control ; Cardiovascular variability
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Chemistry and Pharmacology , Medicine
    Notes: Abstract A unifying general approach to measure regularity, synchronisation and co-ordination is proposed. This approach is based on conditional entropy and is specifically designed to deal with a small amount of data (a few hundred samples). Quantitative and reliable indexes of regularity, synchronisation and co-ordination (ranging from 0 to 1) are derived in a domain (i.e. the information domain) different from time and frequency domains. The method is applied to evaluate regularity, synchronisation and co-ordination among cardiovascular beat-to-beat variability signals during sympathetic activation induced by head-up tilt (T), during the perturbing action produced by controlled respiration at 10, 15 and 20 breaths/min (CR10, CR15 and CR20), and after peripheral muscarinic blockade provoked by the administration of low and high doses of atropine (LD and HD). It is found that: (1) regularity of the RR interval series is around 0.209; (2) this increases during T, CR10 and HD; (3) the systolic arterial pressure (SAP) series is more regular (0.406) and its regularity is not affected by the specified experimental conditions; (4) the muscle sympathetic (MS) series is a complex signal (0.093) and its regularity is not influenced by HD and LD; (5) the RR interval and SAP series are significantly, though weakly, synchronised (0.093) and their coupling increases during T, CR10 and CR15; (6) the RR interval and respiration are coupled (0.152) and their coupling increases during CR10; (7) SAP and respiration are significantly synchronised (0.108) and synchronisation increases during CR10; (8) MS and respiration are uncoupled and become coupled (0.119) after HD; (9) the RR interval, SAP and respiration are significantly co-ordinated (0.118) and co-ordination increases during CR10 and CR15; (10) during HD the co-ordination among SAP, MS and the respiratory signal is larger than that among the RR interval, SAP, MS and the respiratory signal, thus indicating that the RR interval contributes towards reducing co-ordination.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Medical & biological engineering & computing 40 (1992), S. 225-233 
    ISSN: 1741-0444
    Keywords: Time-warping analysis ; Dynamic programming theory ; Signal averaging ; Acoustic quantification ; Left-ventricular function ; Echocardiography
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Chemistry and Pharmacology , Medicine
    Notes: Abstract The cardiac left-ventricular (LV) volume signal, obtained by acoustic quantification, is affected by noise and respiratory modulation, resulting in a large beat-to-beat variability that affects the computation of LV function indices. A new method is proposed to improve the evaluation of LV indices by applying a signal averaging technique based on dynamic time warping to consecutive LV volume waveforms. Volume signals obtained from ten normal young (NY) subjects (mean age±SD: 25±5 years) were used to evaluate the performance of this algorithm. To evaluate its clinical utility, the effects of ageing and pharmacologically induced changes on LV function were assessed by studying, respectively, ten normal (N) adult subjects (age 64±8 years) and ten patients with dilated cardiomyopathy during a control and low-dose dobutamine (10 μg kg−1 min−1) study. Indices of LV function were highly consistent, with a variability of less than 8%, even when only 16 beats were averaged, independently of their selection inside the whole recording. When compared with beat-to-beat measures, the averaging of 16 beats significantly reduced (by more than 50%) the interbeat variability of all indexes. Expected alterations in both diastolic and systolic function were evidenced both with ageing (peak filling atrial contraction and ejection rates: from 275±77 ml s−1, 76±30 ml s−1, 230±70 ml s−1, respectively, in NY, to 160±33 ml s−1, 125±39 ml s−1, 163±54 ml s−1 in N) and with dobutamine (peak filling and ejection rates from 160±72 ml s−1 and 183±86 ml s−1 respectively, in control, to 253±75 ml s−1 and 251±105 ml s−1 with dobutamine). Signal averaging with time warping allows fast and improved assessment of LV function.