Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1612-1112
    Keywords: Column liquid Chromatography ; Chemiluminescence detection ; Solid reagent bed ; Quinone detection
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The combination of solid-state peroxyoxalate chemiluminescence detection and post-column chemical reaction systems in liquid chromatography is investigated. Bis-2,4,6-trichlorophenyloxalate (TCPO) is added from a solid reagent bed with the fluorophore, 3-aminofluoranthene, immobilized on glass beads. Hydrogen peroxide generated photochemically by quinone analytes is measured. Flow splitting is shown to be a simple means of reagent addition with a negligible band broadening effect. This system is compared to a more flexible dualpump design. To minimize band broadening in both systems, the reagent bed is located out of the path of the chromatographic effluent. Detection limits are in the sub-picomole range, an imporvement relative to those previously reported with TCPO added in the liquid phase. These systems can be easily be adapted for detection of peroxide generated by other post-column reactions.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 17 (1983), S. 125-131 
    ISSN: 1612-1112
    Keywords: Miniaturized HPLC ; Post-column reaction detection ; Catecholamines ; Packed-bed reactors ; Non-segmented open-tubular reactors
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The use of non-segmented flow, post-column reaction detection is evaluated for use with miniaturized HPLC. Non-segmented open-tubular reactors with internal diameters 0.1 mm to 0.25 mm and packed-bed reactors with internal diameters of 1 mm, filled with 5 and 10 μm particles are evaluated theoretically and experimentally with respect to band broadening and pressure drop characteristics. An integrated system consisting of miniaturized HPLC (1 mm i. d.) columns and compatible hardware is described. An example of the separation of catecholamines is given.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...