    ISSN: 1619-7089
    Keywords: Key words: Arrhythmias ; Imaging ; Tomography ; Infarct size ; Defibrillator
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract. Infarct size as determined by perfusion imaging is an independent predictor of mortality after implantable cardioverter defibrillator (ICD) implantation in patients with coronary artery disease (CAD) and life-threatening ventricular arrhythmias (VA). However, its value as a predictor of VA recurrence and hospitalisation after ICD implantation is unknown. Therefore, the objective of this study was to evaluate whether infarct size as determined by perfusion imaging can help to identify patients who are at high risk for recurrence of VA and hospitalisation after ICD implantation.We studied 56 patients with CAD and life-threatening VA. Before ICD implantation, all patients underwent a uniform study protocol including a thallium-201 stress-redistribution perfusion study. A defect score as a measurement of infarct size was calculated using a 17-segment 5-point scoring system. Study endpoints during follow-up were documented episodes of appropriate anti-tachycardia pacing and/or shocks for VA and cardiac hospitalisation for electrical storm (defined as three or more appropriate ICD interventions within 24 h), heart failure or angina. After a mean follow-up of 470±308 days, 22 patients (39%) had recurrences of VA. In univariate analysis, predictors for recurrence were: (a) ventricular tachycardia (VT) as the initial presenting arrhythmia (86% vs 59% for patients without ICD therapy, P=0.04), (b) treatment with β-blockers (36% vs 68%, P=0.03) and (c) a defect score (DS) ≥20 (64% vs 32%, P=0.03). In multivariate analysis, VT as the presenting arrhythmia (χ2=5.51, P=0.02) and a DS ≥20 (χ2=4.22, P=0.04) remained independent predictors. Cardiac hospitalisation was more frequent in patients with a DS ≥20 (44% vs 13% for patients with DS 〈20, P=0.015) and this was particularly due to more frequent hospitalisations for electrical storm (24% vs 3% for patients with DS〈20, P=0.037). The extent of scarring determined by perfusion imaging can separate patients with CAD into high- and low-risk groups for recurrence of VA and cardiac hospitalisation after ICD implantation.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1439-6327
    Keywords: Central command ; Muscle chemoreflexes ; Pulsatility index ; Splanchnic circulation ; Isometric exercise
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract The splanchnic circulation can make a major contribution to blood flow changes. However, the role of the splanchnic circulation in the reflex adjustments to the blood pressure increase during isometric exercise is not well documented. The central command and the muscle chemoreflex are the two major mechanisms involved in the blood pressure response to isometric exercise. This study aimed to examine the behaviour of the superior mesenteric artery during isometric handgrip (IHG) at 30% maximal voluntary contraction (MVC). The pulsatility index (PI) of the blood velocity waveform of the superior mesenteric artery was taken as the study parameter. A total of ten healthy subjects [mean age, 21.1 (SEM 0.3) years] performed an IHG at 30% MVC for 90 s. At 5 s prior to the end of the exercise, muscle circulation was arrested for 90 s to study the effect of the muscle chemoreflex (post exercise arterial occlusion, PEAO). The IHG at 30% MVC caused a decrease in superior mesenteric artery PI, from 4.84 (SEM 1.57) at control level to 3.90 (SEM 1.07) (P = 0.015). The PI further decreased to 3.17 (SEM 0.70) (P = 0.01) during PEAO. Our results indicated that ergoreceptors may be involved in the superior mesenteric artery vasodilatation during isometric exercise.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability