Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    AIChE Journal 2 (1956), S. 215-218 
    ISSN: 0001-1541
    Keywords: Chemistry ; Chemical Engineering
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Process Engineering, Biotechnology, Nutrition Technology
    Notes: The design and operation of a windowed autoclave suitable for studying corrosion of materials by pressurized hot water are described. The technique for taking time-lapse motion pictures of a specimen from the instant of contact with the high-temperature water until the corrosion is complete is explained, and a set of typical pictures is presented showing the progress of the attack. Pressure and temperature measurements provide a means for rough computation of corrosion rates, as is shown by the results of two tests of uranium specimens subjected to pressurized hot water.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 19 (1996), S. 213-216 
    ISSN: 0935-6304
    Keywords: Supercritical fluid chromatography ; Open-tubular column ; Dual detection ; Chemiluminescent nitrogen detection ; Flame ionization detection ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The use of a simultaneous detection system for open-tubular supercritical fluid chromatogrphic separation of aniline isomers, alkyl(C8 to C18)dimethylamines, a dialkylmethylamine mixture, and an extract of a Japanese horseradish power “Wasabi” is demonstrated. A chemiluminescent nitrogen detector (CLND) and a flame ionization detector (FID) were configured at the end of the open tubular column via a zero- to dead-volume tee. The dual detection was achieved with a post-column split at a 1:2.5 ratio for the CLND and FID, respectively. The optimized CLND showed virtually no response to non-nitrogenous components such as benzene, toluene, and methanol which were used as injection solvents in these applications.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Basel : Wiley-Blackwell
    Die Makromolekulare Chemie, Rapid Communications 4 (1983), S. 739-744 
    ISSN: 0173-2803
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Physics
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...