Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1438-2385
    Keywords: Key words Meat ; Thiamine ; Capillary electrophoresis ; High performance liquid chromatography
    Source: Springer Online Journal Archives 1860-2000
    Topics: Process Engineering, Biotechnology, Nutrition Technology
    Notes: Abstract  A new capillary electrophoresis (CE) method for the analysis of thiamine in meat is proposed. Samples were submitted to acidic and enzymatic hydrolysis and the extracts were purified using ethanol and an ion exchange column. The thiamine content was determined by CE using 100 mM sodium tetraborate, 50 mM sodium phosphate (pH 7.6), 50 mM sodium dodecyl sulphate and 10% isopropyl alcohol as a separation buffer solution. The analysis was carried out at 15 kV and 50  °C in a 70 cm effective length× 75 μm i.d. fused-silica capillary using on-column UV detection at 254 nm and 7 s injection time (27 nl injection volume). The results obtained by CE for thiamine contents in meat were compared to those obtained by HPLC using an ion-pair reverse phase column with post-column derivatization and fluorescence detection.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 21 (1998), S. 81-86 
    ISSN: 0935-6304
    Keywords: Available niacin ; capillary electrophoresis ; total niacin ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: ---Available and total niacin content in lentils and faba beans have been analyzed by capillary electrophoresis (CE), and the results compared with those obtained by high performance liquid chromatography (HPLC). Acidic and enzymatic hydrolysis have been carried out for available niacin determination, and an alkaline extraction performed for total niacin. The extracts were subsequently purified using a strong anion exchanger resin. Precise conditions for purification had to be worked out for each one of the two analytical methods (HPLC and CE). The HPLC analysis for available and total niacin was carried out in an ion-pair reverse phase column with UV detection at 261 nm. For the CE separation, the following conditions were employed: a 20 mM sodium tetraborate; 15 mM sodium dodecyl sulfate and 20% isopropyl alcohol solution as separation buffer; 30 kV and 25 or 30°C. Separation was carried out in a 70 cm effective length × 75 μm i.d. fused-silica capillary using on-column UV detection at 254 nm. The results obtained by CE for lentils and faba beans were similar to those obtained by HPLC.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource