Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Neonatal jaundice  (2)
  • Chemistry  (1)
  • 1
    ISSN: 1437-9813
    Keywords: Key words Technetium Tc-99m disofenin ; cholescintigraphy ; Biliary atresia ; Ultrasonography ; Neonatal hepatitis ; Neonatal jaundice
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract  Technetium Tc-99m disofenin cholescintigraphy (CS) and ultrasonography (US) are two major clinical methods used in differentiating biliary atresia (BA) from neonatal jaundice. To compare the diagnostic utility of these two modalities, 66 patients with neonatal cholestasis (15 BA, 3 choledochal cyst (CC), 32 neonatal hepatitis, 13 prolonged jaundice, 2 total parenteral nutrition, and 1 sepsis) underwent Tc-99m disofenin CS and US. The diagnostic sensitivity, specificity, and accuracy of CS in differentiating BA from other forms of neonatal jaundice was 100%, 87.5%, and 90.5%, respectively, and for US 86.7%, 77.1%, and 79.4%, respectively. Tc-99m disofenin CS after premedication with phenobarbital and cholestyramine is a convenient and reliable method of differentiating BA from neonatal hepatitis, with a diagnostic accuracy superior to that of US. However, US is the initial imaging procedure of choice in patients presenting with jaundice to rule out anatomic anomalies such as CC.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1437-9813
    Keywords: Technetium Tc-99m disofenin cholescintigraphy ; Biliary atresia ; Ultrasonography Neonatal hepatitis ; Neonatal jaundice
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Technetium Tc-99m disofenin cholescintigraphy (CS) and ultrasonography (US) are two major clinical methods used in differentiating biliary atresia (BA) from neonatal jaundice. To compare the diagnostic utility of these two modalities, 66 patients with neonatal cholestasis (15 BA, 3 choledochal cyst (CC), 32 neonatal hepatitis, 13 prolonged jaundice, 2 total parenteral nutrition, and 1 sepsis) underwent Tc-99m disofenin CS and US. The diagnostic sensitivity, specificity, and accuracy of CS in differentiating BA from other forms of neonatal jaundice was 100%, 87.5%, and 90.5%, respectively, and for US 86.7%, 77.1%, and 79.4%, respectively. Tc-99m disofenin CS after premedication with phenobarbital and cholestyramine is a convenient and reliable method of differentiating BA from neonatal hepatitis, with a diagnostic accuracy superior to that of US. However, US is the initial imaging procedure of choice in patients presenting with jaundice to rule out anatomic anomalies such as CC.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Bognor Regis [u.a.] : Wiley-Blackwell
    Journal of Polymer Science Part B: Polymer Physics 34 (1996), S. 193-199 
    ISSN: 0887-6266
    Keywords: positronium lifetime distribution ; PP/EPDM blend ; free-volume distribution ; phase interaction ; impact strength ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Physics
    Notes: Positron annihilation lifetime measurements were performed on pure polypropylene (PP), ethylene-propylene-diene monomer (EPDM) rubber, and their blends PP/EPDM with a series of EPDM volume fraction φ (= 10-40%). A numerical Laplace inversion technique (i.e., CONTIN algorithm), was employed to obtain the probability distribution functions (PDF) of free-volume radius. We observed that, first, the average free-volume radius in PP/EPDM blends is generally same as that in PP and is much smaller than that in EPDM. Second, the standard deviation σR or the width of the free-volume radius PDF in the blend decreases with φ in the region of φ = 10ndash;30%, and it increases when φ increases from 30% to 40%. The difference in the σR of the blend and the calculated value σc R according to the simple-mixing rule of PP and EPDM is interpreted by the existence of the two-phase interaction (i.e., the residual thermal pressure and shear stress between PP and EPDM phases in the PP/EPDM blends). The correlation between σR, which indicates the interaction of two phases, and the impact strength of PP/EPDM blends was found and discussed. © 1996 John Wiley & Sons, Inc.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...