Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Chemistry  (1)
  • Spontaneous pneumothorax  (1)
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Surgical endoscopy and other interventional techniques 6 (1992), S. 189-192 
    ISSN: 1432-2218
    Keywords: Thoracoscopic surgery ; Wedge resection ; Spontaneous pneumothorax ; Peripheral bronchial carcinoma
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary Thoracoscopic surgery is decidedly expanded by the ability to perform pulmonary wedge resections of the lung by using the Endo-GIA-stapler. In addition to thoracoscopic biopsies, since July 1991 we have carried out wedge resections in 12 patients suffering from spontaneous pneumothorax (nine) or peripheral bronchial carcinoma (three). Postoperatively one air fistula persisted over 9 days. The chest tube was removed within 48 h in all other patients. There was no other major complication. The postoperative hospitalization period lasted 4.6 days (1–9 days). Operating time was 44 min (30–70 min). The benefit for the patient consists in the little-impaired breathing mechanics, the short hospital stay, and the favorable cosmetic result.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 0269-3879
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine
    Notes: A high performance liquid chromatographic method for the determination of the photodynamic chemotherapeutic agent 5,10,15,20-tetra(m-hydroxyphenyl)chlorin (m-THPC) in human plasma following intravenous infusion is described. The procedure involves extraction of the drug in plasma with methanol/dimethyl sulphoxide (4:1 v/v) containing 5,10,15,20-tetra(p-hydroxyphenyl)clorin as the internal standard and separation on a C18 reversed phase column with acetonitrile:0.1% trifluoroacetic acid (77:23 v/v) as the mobile phase. The drug was detected specifically and sensitively at its absorption maximum of 423 nm with a detection limit of 15 ng/mL (signal-to-noise ratio of 5). The intra- and inter-assay coefficients of variation (CV) on analysis of a plasma spiked with m-THPC (1 μg/mL) were 2.3 and 3.4% (n=6), respectively.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...