Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Chemistry  (1)
  • Technetium-99m hexamethylpropylene amine oxime  (1)
  • 1
    ISSN: 1619-7089
    Keywords: Technetium-99m hexamethylpropylene amine oxime ; Labelled leucocytes ; Indium-111 immunoglobulin ; Inflammatory bowel disease ; Dual tracer studies
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Technetium-99m hexamethylpropylene amine oxime (HMPAO) labelled leucocytes and indium-111 polyclonal immunoglobulin (IgG) were simultaneously injected into a group of 27 patients routinely referred for the investigation of inflammatory bowel disease (IBD). Ten-minute anterior abdomen and tail on detector views were obtained at 30 min, 4 h and 24 h p.i. of both tracers. The diagnosis of IBD was obtained in all cases by endoscopy with biopsy and/or surgery. Images were blindly evaluated by two experienced observers who only knew of the clinical suspicion of IBD. IBD was confirmed in 20 patients (12 with Crohn's disease and eight with ulcerative colitis). Sensitivity, specificity and accuracy were 100%, 85% and 96% respectively for labelled leucocytes and 70%, 85% and 74% for IgG. Both IgG and leucocyte scans were normal in six out of seven patients in whom a diagnosis of IBD was excluded; the remaining patient, with ischaemic colitis, was falsely positive with both agents. As far as disease extension is concerned, the IgG study localized 27 diseased segments, whereas 49 were seen with the leucocyte study. Eighty-four segments were normal and 25 showed tracer uptake with both agents. Twenty-four were positive only with the leucocyte study and two were positive only with the IgG study. Agreement between the agents was 80.7%. These results confirm that111In-human polyclonal scintigraphy is less sensitive than99mTc-HMPAO scintigraphy both for the diagnosis of IBD and in the evaluation of disease extension. Nevertheless, if leucocyte labelling is not available, labelled IgG can be used only for diagnostic purposes.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 129-130 
    ISSN: 0935-6304
    Keywords: GC-MS ; kava pyrones ; Alpinia zerumbet ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...