Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1432-0428
    Keywords: Key words Non-insulin-dependent diabetes mellitus ; vitamin D ; vitamin D deficiency ; total insulin ; specific insulin ; proinsulin ; 32 ; 33 split proinsulin ; C-peptide ; glucose intolerance.
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary Vitamin D deficiency reduces insulin secretion and still occurs in East London Asians in whom the prevalence of diabetes mellitus is at least four times that of Caucasians. Vitamin D status was assessed in 44 of 65 non-diabetic subjects ’at risk' of diabetes (spot blood glucose level 〉 6.0 mmol/l 〈 2 h post cibum, or 〉 4.6 mmol/l 〉 2 h post cibum on two separate occasions) and in 15 of 60 age and sex-matched ’low-risk' control subjects who attended for oral glucose tolerance test (OGTT) after screening of 877 omnivorous subjects not known to have diabetes. It was found that 95 % of at-risk and 80 % of low-risk subjects were vitamin D deficient (serum 25-hydroxy-vitamin D 〈 11 ng/ml). Diabetes was present in 16, impaired glucose tolerance in 12 and normoglycaemia in 19 at-risk subjects, impaired glucose tolerance in 2, and normoglycaemia in 13 low-risk subjects. Correlations of 30-min OGTT blood glucose, specific insulin and C-peptide levels with 25-hydroxy-vitamin D concentrations in 44 at-risk subjects were −0.31 (p = 0.04), 0.59 (p = 0.0001) and 0.44 (p = 0.006). In 15 ’not-at-risk' subjects 30-min OGTT specific insulin and C-peptide levels correlated with 25-hydroxy-vitamin D, r = 0.39 (p = 0.04) and 0.16 (p = 0.43), respectively. Serum alkaline phosphatase concentration was higher in at-risk than not-at-risk subjects (59.6 vs 46.5 IU/l, p = 0.012); corrected calcium concentrations were comparable (2.38 vs 2.39 mmol/l, p = 0.7). Following treatment with 100,000 IU vitamin D by i. m. injection, specific insulin, C-peptide [30 min on OGTT] and 25-hydroxy-vitamin D concentrations had risen 8–12 weeks later [means ± SD] from 57 ± 62 to 96.2 ± 82.4 mU/l [p = 0.0017], 1.0 ± 0.4 to 1.7 ± 0.8 pmol/ml [p = 0.0001] and 3.6 ± 1.8 to 13.5 ± 7.4 ng/ml [p = 0.0001], (but not to low-risk group values of 179 ± 89 mU/l, 2.7 ± 1.14 pmol/ml and 8.16 ± 6.4 ng/ml), respectively. Both total serum alkaline phosphatase and corrected calcium concentrations rose following vitamin D treatment in the at-risk subjects by 11.1 ± 8.22 (from 44 to 55 IU/l) and 0.15 ± 0.18, (2.43 to 2.57 mmol/l), respectively (p = 0.004). Abnormal glucose tolerance was unchanged by vitamin D treatment. The value of early and sustained repletion with vitamin D in diabetes prophylaxis should be examined in communities where vitamin D depletion is common. [Diabetologia (1995) 38: 1239–1245]
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1432-0428
    Keywords: Non-insulin-dependent diabetes mellitus ; vitamin D ; vitamin D deficiency ; total insulin ; specific insulin ; proinsulin ; 32,33 split proinsulin ; C-peptide ; glucose intolerance
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary Vitamin D deficiency reduces insulin secretion and still occurs in East London Asians in whom the prevalence of diabetes mellitus is at least four times that of Caucasians. Vitamin D status was assessed in 44 of 65 non-diabetic subjects ‘at risk’ of diabetes (spot blood glucose level 〉6.0 mmol/l 〈2 h post cibum, or 〉4.6 mmol/l 〉2 h post cibum on two separate occasions) and in 15 of 60 age and sex-matched ‘low-risk’ control subjects who attended for oral glucose tolerance test (OGTT) after screening of 877 omnivorous subjects not known to have diabetes. It was found that 95% of at-risk and 80% of low-risk subjects were vitamin D deficient (serum 25-hydroxy-vitamin D 〈11 ng/ml). Diabetes was present in 16, impaired glucose tolerance in 12 and normoglycaemia in 19 at-risk subjects, impaired glucose tolerance in 2, and normoglycaemia in 13 low-risk subjects. Correlations of 30-min OGTT blood glucose, specific insulin and C-peptide levels with 25-hydroxy-vitamin D concentrations in 44 at-risk subjects were −0.31 (p=0.04), 0.59 (p=0.0001) and 0.44 (p=0.006). In 15 ‘not-at-risk’ subjects 30-min OGTT specific insulin and C-peptide levels correlated with 25-hydroxy-vitamin D, r=0.39 (p=0.04) and 0.16 (p=0.43), respectively. Serum alkaline phosphatase concentration was higher in at-risk than not-at-risk subjects (59.6 vs 46.5 IU/l, p=0.012); corrected calcium concentrations were comparable (2.38 vs 2.39 mmol/l, p=0.7). Following treatment with 100,000 IU vitamin D by i.m. injection, specific insulin, C-peptide [30 min on OGTT] and 25-hydroxy-vitamin D concentrations had risen 8–12 weeks later [means±SD] from 57±62 to 96.2±82.4 mU/l [p=0.0017], 1.0±0.4 to 1.7±0.8 pmol/ml [p=0.0001] and 3.6±1.8 to 13.5±7.4 ng/ml [p=0.0001], (but not to low-risk group values of 179±89 mU/l, 2.7±1.14 pmol/ml and 8.16±6.4 ng/ml), respectively. Both total serum alkaline phosphatase and corrected calcium concentrations rose following vitamin D treatment in the at-risk subjects by 11.1±8.22 (from 44 to 55 IU/l) and 0.15±0.18, (2.43 to 2.57 mmol/l), respectively (p=0.004). Abnormal glucose tolerance was unchanged by vitamin D treatment. The value of early and sustained repletion with vitamin D in diabetes prophylaxis should be examined in communities where vitamin D depletion is common.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 0951-4198
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Physics
    Notes: A novel procedure based on electrospray tandem mass spectrometry (ESI-MS/MS) has been used in the diagnosis of organic acidemias. The method is based on the determination of acylcarnitine profiles from blood spots collected on Guthrie cards. The acylcarnitines are extracted with methanol, derivatized to their butyl esters and analyzed by ESI-MS/MS. Precursor-ion scanning of the common fragment at m/z 85 of the butyl esters yields highly diagnostic acylcarnitine profiles. Analysis time is one minute per sample and is fully automated. Examples are given of normal profiles, of profiles from two patients with fatty acid oxidation defects, and of a case of propionic acidemia. The technique is simple, rapid and specific, and shows potential for routine application in neonatal screening of organic acidemias.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Rapid Communications in Mass Spectrometry 4 (1990), S. 447-448 
    ISSN: 0951-4198
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Physics
    Notes: A 4-sector EBEB mass spectrometer, fitted with a liquid secondary-ion mass spectrometer (Cs+) ion source and an array detector has been in use at UCSF for the past 18 months. Using this period, calibration procedures have been developed and operating software refined such that the instrument can now be operated in the tandem mass spectrometry (MS/MS) mode using the array on a routine basis and with a high sample throughput. The instrument has been applied successfully to the analysis of a wide range of peptides, up to molecular weights in excess of 2500. The array is usually operated with a mass resolution of about 1500 full width at half maximum (FWHM), and under these conditions a fragment ion dynamic range of 3000:1 is obtainable. Mass assignment is typically reproducible to within 0.1 u.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Chichester [u.a.] : Wiley-Blackwell
    Surface and Interface Analysis 1 (1979), S. 104 
    ISSN: 0142-2421
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Physics
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    ISSN: 0142-2421
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Physics
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Chichester [u.a.] : Wiley-Blackwell
    Surface and Interface Analysis 24 (1996), S. 187-192 
    ISSN: 0142-2421
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Physics
    Notes: X-ray photoelectron spectroscopy (E-X) imaging has been applied to the study of perfluorinated self-assembled monolayers (SAM) adsorbed on gold surfaces. Patterned monolayers were formed using a ‘stamping’ procedure which enabled the formation of ‘two-component’ monolayers. TheE-X images yield spatial information, with a30 μm resolution, on the quality and chemical composition of the resulting monolayer structures.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    ISSN: 0030-493X
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A method for obtaining collisional activation spectra at much higher resolving power than before by use of a collision chamber and a B/E linked scan, is described.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    ISSN: 0306-042X
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A method is described to confirm the presence of 19-nortestosterone metabolites in urine after the administration of veterinary preparations of this anabolic steroid to horses. The method is based upon the detection, by gas chromatography mass spectrometry or selected ion monitoring, of an isomer of estrane-3,17-diol in the urine.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    New York : Wiley-Blackwell
    Journal of Polymer Science: Polymer Letters Edition 16 (1978), S. 461-464 
    ISSN: 0360-6384
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...