Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Electrophoresis 16 (1995), S. 510-515 
    ISSN: 0173-0835
    Keywords: Capillary electrophoresis ; Micellar electrokinetic chromatography ; Peptide sequencing ; Phenylthiohydantoin-amino acids ; Chemistry ; Biochemistry and Biotechnology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Chemistry and Pharmacology
    Notes: Separations of twenty phenylthiohydantoin (PTH) amino acids, and amino acid derivatives, resulting from the Edman degradation of peptides and proteins, were optimized for peptide sequencing by capillary electrophoresis. Manual sequencing of angiotensin II was performed by Edman degradation and capillary electrophoresis of the PTH amino acid obtained after each cycle. The results were compared with those of an automated conventional protein sequencer. Interfacing capillary electrophoresis with Edman degradation provides an additional option for protein sequencing.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 0173-0835
    Keywords: Capillary electrophoresis ; Protein detection ; Fluorescence labeling ; Laser-induced fluorescence ; Chemistry ; Biochemistry and Biotechnology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Chemistry and Pharmacology
    Notes: A low-cost and highly sensitive laser-induced fluorescence detector for on-column detection systems was constructed and its applications were demonstrated in protein separation by capillary electrophoresis. The limit of detection (LOD) at a signal-to-noise ratio of 2 for Lissamine 20 was about 1.4 × 10-21 mole at 10 nL sample injection and the relative standard deviation (RSD) for 1.5 × 10-11 M of Lissamine 20 solution was about 15%. These values are comparable to or even better than those reported using a similar on-column detection system. This sensitive LIF detection was applied for the study of tryptic digestion of insulin and for urinary protein profiling.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 0173-0835
    Keywords: Chemistry ; Biochemistry and Biotechnology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Chemistry and Pharmacology
    Notes: The factors affecting micellar electrokinetic capillary chromatographic separation of hippuric and o-, m-, p-methylhippuric acid were investigated by changing the species of micelles, and adding urea to the micellar solution. The analysis of hippurates in human urine is demonstrated under optimum conditions using 20 mM phosphate buffer (pH 8.0) containing 100 mM dodecyltrimethylammonium bromide and 4 M urea at -22 kV applied voltage. This method proved suitable for the screening of hippurates in human urine following occupational exposure to toluene and xylene.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...