ISSN:
1573-9686
Schlagwort(e):
Puncture test
;
Probe diameter
;
Chorioamnion
;
Membrane characteristics
Quelle:
Springer Online Journal Archives 1860-2000
Thema:
Medizin
,
Technik allgemein
Notizen:
Abstract To further the characterization of the chorioamniotic membrane’s physical properties, we assessed its ability to withstand a concentrated force. Probes of various diameters were used to puncture 275 specimens from 11 membranes. Values for “strength”/thickness, “stiffness”/thickness, and “toughness”/thickness all showed positive linear correlations (p〈0.001) with the increase ofd/D, the ratio of probe diameter to specimen diameter. “Ductility” was independent of diameter, though a logarithmic regression did fit the data marginally (p〈0.05). The separate fracture of the amnion and chorion, which is reflected in ductility measurements, results in an increase in the distance the membrane can be deflectedin vitro. In vivo, this behavior would translate to a reduction of pressure exerted on the remaining membrane, while the integrity of the protective sac is maintained. The data pool of mechanical characteristics was enlarged by reconciling data that were gathered by either of two testing methods: puncturing or bursting; the latter method involves the application of force over the entire surface of the test specimen.
Materialart:
Digitale Medien
URL:
http://dx.doi.org/10.1007/BF02367090
Permalink