  • 1
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 2 (1979), S. 172-176 
    ISSN: 0935-6304
    Keywords: Chromatography, LC and GC ; Capillary ; Theory ; Ultimate resolution ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The expression for the resolution function, R, in terms of operating parameters for open tubular columns has been extended to include inlet contributions to the peak variance. Subsequent optimization has revealed the existence of optima in the column radius, the stationary phase thickness and the diffusion coefficient ratio in the stationary and mobile phases-in addition to the well-known optimum in the flow velocity. This implies that R at optimum becomes R=f(K)L0.6Vi-0.2, i.e. a function only of the column length, L, the inlet volume, Vi, and the concentration distribution coefficient, K. For given K, L and Vi all other parameters such as retention time and pressure drop can thus be directly computed. The information is finally consolidated in the form of contour diagrams. The text itself is cast in the form of a science fantasy.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 1 (1978), S. 41-46 
    ISSN: 0935-6304
    Keywords: Chromatography ; Theory ; Chromatographic systems analysis ; Real plate number ; Fundamental interpretation ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The real plate number concept is interpreted in terms of the fundamental properties of a chromatograph. It is shown that the linear relationship between the total peak width at half height, (b0.5)T, t, and k is only an approximation of the more general linear relationship between (b0.5)2T, t and (1 + k)2. In the case where the relationship between (b0.5)T, t and k approaches linearity, it is concluded, firstly, that b0 = a, i. e., b0 is a column property and independent of extra-column phenomena and, secondly, that nreal=ntheor. When the relationship becomes non-linear, b0 is determined partly by extra-column phenomena, but not in terms of a useful relationship. It is concluded that it is unnecessary to introduce the parameters a, b0 and nreal, since they all have counterparts in the established theory of chromatography. These counterparts prove to be equally useful in the practical analysis of chromatographic systems.