Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Column liquid chromatography  (1)
  • MS detection  (1)
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 33 (1992), S. 147-150 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; MS detection ; Metachlor ; Herbicide residues ; Tomatoes
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A gas chromatograph/mass selective detector method is presented for the analysis of the major metabolic residues of metolachlor by acid hydrolysis of tomato fruit. The two major hydrolysis products, CGA-37913 (2-[2-ethyl-6-methylphenyl]amino-1-propanol) and derivatised CGA-49751 (4-[2-ethyl-6-methylphenyl]-2-hydroxy-5-methyl-3-morpholinone) were monitored in the selective ion mode atm/z 162 andm/z 160, respectively. Recoveries from 87 to 96% were obtained for tomato fortified at 50 to 200μg kg−1. The proposed method of analysis will allow for a detection limit of 11 μg kg−1 for CGA-37913 and 12 μg kg−1 for the derivatised CGA-49751.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Soyabean leaf extracts ; Kaempferol glycosides ; Kaempferol
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary An HPLC method is described for the determination of kaempferol glycosides in soybean leaf extracts. The method is rapid and can provide qualitative and relative quantitative results for 9 kaempferol glycosides. The flavonol glycosides are extracted from soybean leaves by shaking the samples in 50% methanol; the extracts are filtered, evaporated to dryness and reconstituted in methanol before further purification through a C-18 Sep-Pak column. The samples are injected onto a C-18 HPLC column, separated by gradient elution with a 1% phosphoric acid: methanol mixture and detected on a UV/VIS diode-array detector. Flavonols were monitored at 265 and 348 nm and spectra from 180 to 400 nm were stored and used as an aid in identification. Relative quantities of the kaempferol glycosides among soybean cultivars were calculated from their proportion of peak area in the chromatograms. Total kaempferol concentration of the extracts was calculated after acid hydrolysis of the kaempferol glycosides to the aglycone and comparison of peak areas to kaempferol standards.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...