Bibliothek

feed icon rss

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
  • 1
    Digitale Medien
    Digitale Medien
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 14 (1991), S. 681-685 
    ISSN: 0935-6304
    Schlagwort(e): Computer-aided column design ; Computer-assisted optimization ; Selectivity-tuned capillary columns ; Series-coupled capillary columns ; Purgeable compounds ; Waste water ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: This report describes the application of a computer-aided column design and optimization program to the analysis of purgeable compounds in waste water. Series-coupled columns with dissimilar phases can be “selectivity-tuned” to provide the maximum separation factors, thus facilitating the most rapid analysis. A computer program calculates the column lengths and operating conditions which are required to provide the desired resolution at a specified flow rate.
    Zusätzliches Material: 8 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    ISSN: 0935-6304
    Schlagwort(e): Computer modeling of GC ; computer simulation of GC ; computer-assisted GC analysis ; GC multicolumn analysis ; heart cutting GC analysis ; computer-assisted column design ; computer-assisted selectivity tuning ; retention index mapping ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: ---The analysis of four components in a mixture containing many possible interferents is simplified by heart-cutting serially connected columns containing stationary phases of widely different polarities. The design of the proper lengths of the two columns and timing the heart-cuts is accomplished with the aid of a computer simulation of the problem. The computer program calculates the proper lengths of column to produce the shortest analysis time and also outputs the predicted chromatograms from both columns. The chromatogram from the first column is used to construct the timing gates for the heart-cuts and the chromatogram from the second or analytical column is used to set integration gates for the selected compounds of interest.
    Zusätzliches Material: 7 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...