Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Il nuovo cimento della Società Italiana di Fisica 18 (1996), S. 385-388 
    ISSN: 0392-6737
    Keywords: Mössbauer effect ; other ψ-ray spectroscopy ; Strong field excitation of optical transitions in quantum systems multiphonon processes ; dynamic Stark shift ; Effects of internal magnetic fields ; Conference proceedings
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Summary We have studied the time dependence of Mössbauer absorption in a magnetically soft sample of Fe18Ni82 permalloy under the influence of a radio-frequency (r.f.) magnetic field. Absorption was measured as a function of the r.f. field phase at specific gamma-ray energies. We have shown that measuring the time dependence of absorption makes it possible to differentiate between purely magnetic and magnetoacoustic modulation mechanisms even in cases where clear distinction is not visible in conventional energy domain spectra.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Il nuovo cimento della Società Italiana di Fisica 2 (1983), S. 166-174 
    ISSN: 0392-6737
    Keywords: Biomagnetism (including magnetocardiography) ; Superconducting devices ; superconducting magnets
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Description / Table of Contents: Riassunto Si è costruito un magnetometro SQUID differenziale a 3 canali per la misurazione simultanea delle 3 componenti ortogonali del campo magnetico nella stessa posizione. Si descrive la struttura dell’apparecchio e si mostrano i dati MCG misurati. Si discutono gli effetti d’interferenza tra i canali.
    Notes: Summary We have constructed a three-channel differential SQUID magnetometer for the simultaneous measurement of the three orthogonal components of the magnetic field in the same location. The structure of the device is described and MCG data measured are shown. Interference effects between the channels are discussed.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Il nuovo cimento della Società Italiana di Fisica 2 (1983), S. 301-310 
    ISSN: 0392-6737
    Keywords: Biomagnetism (including magnetocardiography) ; Superconducting devices ; superconducting magnets
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Description / Table of Contents: Riassunto Si confrontano i magnetocardiogrammi misurati in un caso di infarto miocardico anterolaterale con i corrispondenti magnetocardiogrammi simulati. I cambiamenti piú notevoli nell’MCG misurato si sono osservati nelle parti superiori e inferiori del torace come previsto dalla simulazione.
    Notes: Summary The MCGs measured in a case of an anterolateral myocardial infarction were compared with the corresponding simulated MCGs. The most distinctive changes in the measured MCGs were observed in the upper and lower parts of the thorax as predicted by the simulation.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Springer
    Il nuovo cimento della Società Italiana di Fisica 2 (1983), S. 471-483 
    ISSN: 0392-6737
    Keywords: Biomagnetism (including magnetocardiography) ; Superconducting devices ; superconducting magnets
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Description / Table of Contents: Riassunto Le sorgenti di risposte uditive magnetiche ed electtriche stimolate sono state formate con dipoli a corrente multipli. L’attività a livello delle cortecce uditive, 2.6 cm al di sotto della calotta cranica, spiega la distribuzione di campo osservata $$\overline {N100m}$$ . Un’ulteriore sorgente di corrente vicino al vertice è necessaria per spiegare le corrispondenti distribuzioni di potenziale. La posizione delle sorgenti di corrente di $$\overline {N100m}$$ non ha mostrato alcuna dipendenza sistematica dalla frequenza tonale.
    Notes: Summary The sources of auditory evoked electric and magnetic responses were modelled with multiple current dipoles. The activity at the auditory cortices, 2.6 cm beneath the skull, explains the observed $$\overline {N100m}$$ field distribution. An additional current source near the vertex is needed to explain the corresponding potential distributions. The locations of the current sources of $$\overline {N100m}$$ did not show any systematic dependence on the tonal frequency.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Springer
    Il nuovo cimento della Società Italiana di Fisica 2 (1983), S. 484-494 
    ISSN: 0392-6737
    Keywords: Biomagnetism (including magnetocardiography) ; Superconducting devices ; superconducting magnets
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Description / Table of Contents: Riassunto I movimenti volontari degli arti sono preceduti da spostamenti MEG che cominciano già 1.2s prima del movimento. Questi spostamenti invertono la polarità sull’area di rappresentazione della corteccia motoria dell’arto in questione.
    Notes: Summary Voluntary limb movements are preceded by MEG shifts beginning even as early as 1.2 s before the movement. These shifts reverse polarity above the cortical motor representation area of the limb concerned.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    ISSN: 1741-0444
    Keywords: Risk stratification ; Magnetocardiography ; High-resolution electrocardiography ; Ventricular tachycardia ; Sudden cardiac death ; Myocardial infarction
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Chemistry and Pharmacology , Medicine
    Notes: Abstract A new time-domain analysis method, which quantifies ECG/MCG intra-ORS fragmentation, is applied to parts of the QRS complex to identify postmyocardial infarction patients with ventricular tachycardia. Three leads of signalaveraged electrocardiograms and nine leads of magnetocardiograms were band-pass filtered (74Hz to 180Hz). The filtered signals showed fragmentation in the QRS region, which was quantified by the number of peaks M and a score S, that is the product of M and the sum of the peak amplitudes. Both parameters were determined for the first 80 ms of the QRS complex and the total QRS complex in each channel. For classification, the mean-values of the parameters M and S of the three electrical leads and the nine magnetic leads were calculated. Late potential and late field analyses were performed for the same signals. 31 myocardial infarction patients were included, 20 of them with a history of documented ventricular tachycardia (VT). Identification of VT patients using the SAECG led to better results (sensitivity 95%, specificity 91%) considering the entire QRS complex than with the standard late potential analysis suggested by Simson (sensitivity 90%, specificity 73%). For the SAMCG and the entire QRS complex results using the parameters S and M are also better (sensitivity 95%, specificity 100%) than for the late field analysis (sensitivity 90% and specificity 100%). For the first 80 ms, the performance of the parameters M and S is only slightly decreased.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...