Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Amsterdam : Elsevier
    Biology of the Cell 69 (1990), S. 41-51 
    ISSN: 0248-4900
    Keywords: motility ; myoneme ; nonactin filaments ; polarizing microscopy ; protist
    Source: Elsevier Journal Backfiles on ScienceDirect 1907 - 2002
    Topics: Biology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Amsterdam : Elsevier
    Biology of the Cell 67 (1989), S. 251-261 
    ISSN: 0248-4900
    Keywords: Ca^2^+ regulation ; myoneme ; nonactin filament
    Source: Elsevier Journal Backfiles on ScienceDirect 1907 - 2002
    Topics: Biology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1279-8517
    Keywords: Mandible ; Holographic interferometry ; Static stresses ; Tri-dimensional composites ; Transversal isotropy and anisotropy
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Résumé Afin de tenter de déterminer la nature de la structure mécanique de la mandibule, les auteurs ont respectivement comparé, à l'aide de l'interférométrie holographique, le comportement de mandibules fraîches de cadavre, celui d'une équerre métallique représentative et celui d'un bloc de carbone-carbone 3D sous contraintes statiques. Il n'existe aucune similitude entre le comportement de la mandibule humaine et celui d'un acier polycristallin. A l'inverse, celui de la mandibule et celui du carbone-carbone 3D sont très voisins. Il serait prématuré d'affirmer que le matériau osseux est un composite hétérogène. Tout au plus peut-on démontrer, ce qui est une première approche, qu'il a un comportement très voisin, dans des conditions d'expériences identiques et pour des contraintes identiques. Les auteurs ont également démontré que la mandibule présentait un phénomène d'hystérésis mécanique, c'està-dire que soumise à une contrainte très faible, elle se déforme mais que cette déformation ne tend à s'annuler que partiellement et dans le temps.
    Notes: Summary In order to try to determine the nature of the mechanical structure of the mandible, the authors have compared, with the help of holographic interferometry, the behavior of the fresh mandible of a corpse, of a representative iron angle, and of a block of carbon-carbon under static constraint. There are no similarities between the behavior of the human mandible and that of a polycrystalline steel. On the contrary, the behavior of the mandible and of the carbon-carbon block are very similar. It would be hasty to state that bones are a heterogenous composite. We can only prove, in a first approach, that they behave similarly under identical experimental conditions. The authors also demonstrated that the mandible presents a “mechanical hysteresis” phenomenon. This means that, when subjected to a small strain, its shape changes, but this change tends to neutralize itself in part in the course of time.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 1279-8517
    Keywords: Mandible ; Constraints ; Deformations ; Isotropy ; Anisotropy ; Mechanical fusibles
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Résumé A l'aide de la méthode des éléments finis et d'un ≪ modèle modifié ≫, les auteurs ont étudié les déformations d'une mandibule isolée de son contexte musculaire et soumise à des contraintes statiques. Ont été successivement calculés: la déformation générale de la mandibule et ses modifications en fonction de la direction d'application de la charge, les phénomènes de rotation ou de ≪ vrillage ≫ de coupes de mandibules isolées par l'ordinateur, les déformations respectives des corticales interne et externe. Il a été mis en évidence des phénomènes mécaniques singuliers correspondant aux zones où siègent les formes anatomo-cliniques des fractures mandibulaires. Les auteurs en concluent que la mandibule a le comportement mécanique d'un matériau composite 3D très hétérogène.
    Notes: Summary The authors have studied the deformations of a mandible isolated from its muscular environment and submitted to statical constraints, with the help of a “modified model” and the finite elements method: the general deformation of the mandible and its modifications according to the direction of the application of the pressure, the rotation phenomenon or “torsion” in cross sections (identified by computer) of the mandible, the respective deformations of the internal and external corticals have successively been calculated. Particular mechanical phenomenons corresponding to the areas where the anatomo-clinical forms of the mandibulary fractures take place have clearly been shown. The authors draw the conclusion that the mandible behaves mechanically in a similar way to a tridimentionnal composite.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...