Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Dual-energy X-ray absorptiometry (DXA)  (2)
  • Contraction  (1)
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Osteoporosis international 2 (1992), S. 146-152 
    ISSN: 1433-2965
    Keywords: Dual-energy X-ray absorptiometry (DXA) ; Dual-photon absorptiometry (DPA) ; Total body composition
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Dual-photon absorptiometry (DPA) is a well-established procedure for measuring bone mineral density (BMD). Recently, dual-energy X-ray absorptiomery (DXA) has become available, which has the ability to measure BMD both regionally and in the total body (TB). We have evaluated the in vivo and in vitro precision of a DXA instrument and compared it with a DPA instrument with similar software characteristics. The short-term precision of BMD measurements using DXA was assessed in 65 postmenopausal women who had duplicate scans performed, with repositioning between scans. Precision was 0.9% in the lumbar spine and 1.4% in the femoral neck. The midterm precision of DXA was compared with DPA by scanning 10 volunteers a mean of four times over 24 weeks, on both instruments. The precision of the bone mineral content (BMC) and area measurements was significantly better (P〈0.05) with DXA than with DPA. Long-term in vitro precision was assessed by scanning an aluminium spine phantom over 42 weeks, and a cadaveric sample over 52 weeks, on both instruments. Precision was similar using the aluminium phantom, but was significantly improved (P〈0.001) when using DXA for scanning the cadaveric sample. Highly significant correlations (allP〈0.001) of BMD, BMC and area measurements were observed when 70 volunteers were scanned on both instruments. However, there was a systematic difference in BMD values between the instruments. The precision of TB composition measurements assessed in 16 volunteers, over a 16-week period, were TB BMD 0.65%, TB lean tissue 1.47%, and TB fat tissue 2.73%. The correlation between weight measured by electronic scales and TB mass as measured by DXA, which was assessed in 70 volunteers, was excellent (r=0.99,p〈0.001). We conclude that DXA offers improvements in measuring BMD over DPA in terms of faster scanning times and improved resolution, resulting in better precision, with the additional advantage of the ability to measure TB composition with high precision.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1433-2965
    Keywords: Bone densitometry ; Dual-energy X-ray absorptiometry (DXA) ; Quality control
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract The performance of dual-energy X-ray absorptiometry (DXA) instruments can be monitored using various quality control (QC) procedures. It has not been established which of these is most appropriate. The aim of this study was to determine which of four QC procedures is the best to use for longitudinal monitoring. Eighteen centres with DXA instruments scanned an aluminium spine phantom weekly for up to 16 months, and the bone mineral density data were used for the QC procedures. The methods investigated were the instrument's inbuilt quality assurance (QA) procedure, visual inspection, multi-rule Shewhart control charts, and Cusum analysis using a truncated-V mask. True and false positive fractions (TPF and FPF) of each method were calculated, including those for a range of action levels for the Shewhart charts and dimensions of the Cusum mask. For Shewhart, the action levels giving the most desirable TPF and FPF were whole multiples of the standard deviation (SD). For Cusum, the most desirable mask dimensions were 3.6 SD for the total height of the vertical section and 0.9 SD per data point for the gradient of the wings. Predictive power of each method as a means of fault detection was decided by the number of faults detected out of a total of 8 non-mechanical faults subsequently diagnosed. The inbuilt QA detected 2, visual inspection 7, Shewhart chart 7 and Cusum analysis 7. The FPFs were: visual inspection 0.09, Shewhart 0.04, Cusum 0.08. At these levels of FPF, the average time in days (range) from onset of a fault to detection was 39 (6–82) for visual inspection, 39 (4–116) for Shewhart and 21 (1–49) for Cusum. All three “phantom” methods are excellent for DXA QC, with modified Cusum analysis being the most effective. The inbuilt QA appears of little use on its own for longitudinal QC.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    European journal of plastic surgery 13 (1990), S. 189-191 
    ISSN: 1435-0130
    Keywords: Skin graft donor sites ; Contraction ; Synthetic dressings
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary Many articles have been written about wound contraction. The majority of these use animals as these experiments are impossible to repeat in humans for ethical reasons. Skin graft donor sites have been used in this study as repeatable controlled wounds. Wound contraction does occur in these wounds and it can be reduced by covering the wound with a synthetic dressing.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...