Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Contrast media  (1)
  • Key words: MRI—Hepatic imaging—RARE—Detection—Characterization.  (1)
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    European radiology 7 (1997), S. S178 
    ISSN: 1432-1084
    Keywords: Key words: Magnetic resonance angiography ; Contrast media ; Pulmonary arteries ; Carotid arteries ; Renal arteries
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract. MR angiography (MRA) is a technique under ongoing discussion. Its non-invasiveness and sensitivity to flow irregularities make it an investigational technique which is easy to apply but which does not always lead to comprehensive results. It requires special skill to perform and also experience for correct interpretation of the results. The lengthiness of the procedure combined with certain physical properties tends to limit its use to mostly neurovascular applications. With the introduction of ultrafast MRA in conjunction with peripheral bolus-injection of extracellular contrast media, a new approach to the imaging of such regions as the thoracic and abdominal vasculature not to mention other vascular territories has become possible. In this paper, considerations of bolus and measurement optimization and timing protocols for dedicated indications are presented together with an overview on the experience acquired to date for CE-MRA of the carotid artery, mediastinal and pulmonary vessels, abdominal vasculature, and peripheral vessels. The main advantage of ultrafast CE-MRA is that patients are subjected to much more tolerable breath-hold investigations with the result that physiological motion such as peristalsis or major pulsation is minimised.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1432-0509
    Keywords: Key words: MRI—Hepatic imaging—RARE—Detection—Characterization.
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract. Background: We compared two T2-weighted turbo spin echo (TSE) sequences with a T2-weighted conventional SE (CSE) sequence to determine whether sequences derived from rapid acquisition with relaxation enhancement such as TSE could replace CSE for the detection and subsequent characterization of focal liver lesions. Methods: A total of 55 consecutive patients with 107 liver lesions underwent magnetic resonance imaging examinations at 1.5 Tesla, with a constant imaging protocol. TSE pulse sequences were acquired with eight echo trains (repetition time [TR], 4718 ms; echo time [TE], 90 ms; acquisition time [TA], 4.03 min; and a symmetric k-space ordering scheme) and 11 echo trains (TR, 4200 ms; TE, 140 ms; TA, 4.40 min; and an asymmetric k-space ordering scheme) and compared with CSE (TR, 2300 ms; TE, 45/90 ms; TA, 9.53 min). Images were analyzed qualitatively by scoring image quality and artifacts and counting focal liver lesions by independent reading with consensus obtained for discrepancies. Quantitative analysis was performed by measuring signal-to-noise (S/N), contrast-to-noise (C/N), and tumor–liver signal intensity (T/L) ratios. Results: T2-weighted TSE sequences provided better subjective image quality and reduced artifacts as compared with the T2-weighted CSE sequence. CSE and TSE sequences exhibited no statistically significant differences in liver S/N, lesion–liver C/N (CSE TE, 90 ms: 18.6 ± 14.0; TSE TE, 90 ms: 16.5 ± 12.9) and the detectability of focal liver lesions. Heavily T2-weighted TSE with a TE of 140 ms allowed correct characterization of focal liver lesions based on a T/L ratio of 3.0 in 84% of patients. Conclusions: T2-weighted TSE sequences are as suited as CSE for the detection (TE, 90 ms), and appear to be superior for the characterization (TE, 140 ms), of focal hepatic lesions. Whether a single sequence, such as a double-echo TSE or a single-echo TSE sequence with a TE between 110 and 120 ms, might perform both functions as well or better than CSE is unknown. However, because of time savings, TSE eventually may be preferred over CSE.
    Type of Medium: Electronic Resource