Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Documenta ophthalmologica 75 (1990), S. 303-314 
    ISSN: 1573-2622
    Keywords: Blue-yellow perimetry ; general sensitivity loss ; corrected sensitivity loss ; cataract
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract A perimetric method using blue stimuli on a yellow background was compared with perimetry using white stimulion on a white background as a method of detecting glaucomatous damage. Meridian perimetry was used with an adapted Tübinger perimeter. The difference between the blue-on-yellow meridian and the white-on-white meridian was subdivided into two parts: the general blue sensitivity loss (GBSL), probably due to optical factors, and the corrected blue sensitivity loss (CBSL), probably due to glaucoma. Nine normals, fourteen primary open angle glaucoma (POAG) patients and nine ocular hypertensives (OHT) were tested. All POAG patients and some of the OHT group showed higher CBSL values than the controls. The blue-yellow meridian showed broader and deeper defects than the white-white meridian in all of the POAG group; some of the OHT group had defects in the blue-yellow meridian that were not present in the white-white meridian.In conclusion, blue on yellow perimetry shows promise as a method for more sensitive detection of early glaucomatous damage.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Documenta ophthalmologica 82 (1992), S. 29-31 
    ISSN: 1573-2622
    Keywords: Cornea ; Lubricant ; Ocular ; Optical ; Straylight ; Tear
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract The question was raised whether ocular lubricants or artificial tears might have adverse effects on optical clarity of the eye. Eight current commercial products were tested on five young subjects, using the Straylight Meter. No adverse effects were found.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Documenta ophthalmologica 61 (1986), S. 327-333 
    ISSN: 1573-2622
    Keywords: stray light ; glare ; contrast sensitivity ; cataract ; corneal dystrophy
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract For healthy eyes intraocular light scatter was investigated several decades ago. For pathological eyes, however, little is known. As clinical test several techniques have been proposed but none has gained general acceptance. A disadvantage of these tests was that quantities were estimated that related only indirectly to the amount of light scatter. We propose a method that gives a direct estimate of the light scatter. We studied patients with cataract, corneal dystrophy, iris and fundus hypopigmentation, etc. A remarkable finding was that visual acuity correlates rather weakly with the amount of scatter. Since, however, the amount of scatter causes a considerable loss of visual function, the results show that for these patients the visual acuity test gives a rather limited impression of their visual handicap. More attention to the problems associated with intraocular light scatter is needed.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...