Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Coronary surgery  (1)
  • PACS. 61.12.Ex Neutron scattering techniques (including small-angle scattering) – 75.30.Gw Magnetic anisotropy – 75.50.Tt Fine-particle systems; nanocrystalline materials  (1)
  • PACS. 61.12.Ex Neutron scattering techniques (including small-angle scattering) – 75.30.Gw Magnetic anisotropy – 75.50.Tt Fine-particle systems; nanocrystalline materials – 75.75+aMagnetic properties of nanostructures – 81.07.-b Nanoscale materials and structures: fabrication and characterization  (1)
Material
Years
Keywords
  • Coronary surgery  (1)
  • PACS. 61.12.Ex Neutron scattering techniques (including small-angle scattering) – 75.30.Gw Magnetic anisotropy – 75.50.Tt Fine-particle systems; nanocrystalline materials  (1)
  • PACS. 61.12.Ex Neutron scattering techniques (including small-angle scattering) – 75.30.Gw Magnetic anisotropy – 75.50.Tt Fine-particle systems; nanocrystalline materials – 75.75+aMagnetic properties of nanostructures – 81.07.-b Nanoscale materials and structures: fabrication and characterization  (1)
  • Chemistry  (2)
  • Organic Chemistry  (2)
  • +
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    The European physical journal 26 (2002), S. 57-65 
    ISSN: 1434-6036
    Keywords: PACS. 61.12.Ex Neutron scattering techniques (including small-angle scattering) – 75.30.Gw Magnetic anisotropy – 75.50.Tt Fine-particle systems; nanocrystalline materials
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract: This paper presents a calculation of the magnetic small-angle neutron scattering cross-section resulting from a dilute ensemble of superparamagnetic particles exhibiting uniaxial magnetic anisotropy. We focus on the two experimentally relevant scattering geometries in which the incident neutron beam is perpendicular or parallel to an applied magnetic field, and we discuss several orientations of the anisotropy axes with respect to the field. Magnetic anisotropy has no influence on the magnetic small-angle neutron scattering when the particles are mobile, as is the case e.g. in ferrofluids, but, when the particles are embedded in a rigid non-magnetic matrix and the orientations of the anisotropy axes are fixed, significant deviations compared to the case of negligible anisotropy are expected. For the particluar situation in which the anisotropy axes are parallel to the applied field, closed-form expressions suggest that an effective anisotropy energy or anisotropy-energy distribution can be determined from experimental scattering data.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    The European physical journal 29 (2002), S. 533-540 
    ISSN: 1434-6036
    Keywords: PACS. 61.12.Ex Neutron scattering techniques (including small-angle scattering) – 75.30.Gw Magnetic anisotropy – 75.50.Tt Fine-particle systems; nanocrystalline materials – 75.75+aMagnetic properties of nanostructures – 81.07.-b Nanoscale materials and structures: fabrication and characterization
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract: Based on a micromagnetics model, we develop a method through which quantitative information on the volume-averaged mean-square magnetostatic stray field 〈|H b d|2〉 v due to non-zero divergences of the magnetization M within the bulk of a ferromagnetic body can be obtained by analysis of magnetic-field-dependent small-angle neutron scattering data. In the limit of high applied magnetic field H a, when the direction of M deviates only sligthly from H a, we have estimated a lower bound for 〈|H b d|2〉 v as a function of the external field, and we have applied the method to bulk samples of nanocrystalline electrodeposited Ni and Co and coarse-grained polycrystalline cold-worked Ni. The root-mean-square magnetostatic stray field, which is inherent to a particular magnetic microstructure, shows a pronounced field dependence, with values ranging from about 5 to 50mT. Even at applied fields as large as 1.7T, the quantity μ〈|H b d|2〉1/2 v of nanocrystalline Co is still 24mT, which suggests that contributions to the total magnetostatic field originating from the bulk are significant in nanocrystalline ferromagnets; therefore, 〈|H b d|2〉 v cannot be ignored in the interpretation of e.g. measurements of magnetization or spin-wave resonance. A comparison of 〈|H b d|2〉 v with the volume-averaged mean-square anisotropy field reveals that both quantities are of comparable magnitude.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1432-1238
    Keywords: Postoperative pulmonary function tests ; Coronary surgery
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Pulmonary function tests were measured in 33 male patients undergoing elective coronary artery bypass surgery. Three modes of surgical technique were used: Bilateral internal mammary artery graft (BIMA), single internal mammary artery graft (SIMA) and saphenous vein grafts (VS). Following parameters were recorded: patient's age, length, body weight, preoperative forced vital capacity (FVC) and forced expiratory volume at one second (FEV 1), preoperative end-diastolic pressure and function of the left ventricle, smoking habitus, the fact that the pleural cavity was entered, duration of the cardiopulmonary bypass period, perioperative fluid balance and postoperative FVC and FEV 1 on the first eight postoperative days. In the BIMA group two pleural cavities, the SIMA group one pleural sac and the VS group none of the pleural cavities was entered. The BIMA group was younger (50.1±7.6 versus 57.7±7.28 and 60.1±6.9 years (p〈 0.05)) than the SIMA and VS group. Postoperative external blood loss was lower in the VS group compared to the SIMA and BIMA groups (839±255 ml versus 1346±654 ml and 1259±396 ml (p〈 0.05)). The FVC shows a dramatic decrease especially on the second postoperative day and was most markedly diminished in the BIMA and SIMA compared to VS (31%±9% and 35%±8% versus 45%±10% of preoperative values (p〈 0.05)). Full recovery of the FVC was not achieved eight days after surgery: BIMA and SIMA showing the same tendency versus VS (61%±10%, 60%±8% versus 71%±8% preoperative FVC (p〈 0.05)). FEV 1 had the same evolution: on the second postoperative day a significant reduction for BIMA and SIMA versus VS group (32%±10%, 34%±8% versus 46%±9% of preoperative values (p〈 0.05)) and incomplete recovery after eight days (59%±8% (BIMA), 59%±11% (SIMA) versus 69%±7% (VS) (p〈 0.05)). No statistical difference between SIMA and BIMA group could be shown for FVC and FEV 1. We conclude that coronary artery bypass surgery causes a substantial decrease in FVC and FEV 1 especially when one or two pleural cavities are violated. The reduction of FVC in BIMA is so important that this technique should be restricted to patients with adequate pulmonary reserves.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...