Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Amsterdam : Elsevier
    Free Radical Biology and Medicine 10 (1991), S. 195-200 
    ISSN: 0891-5849
    Keywords: Arachidonic acid ; Assay ; Endocyclization ; Free Radical ; Lipids ; Mass Spectrometry ; Peroxidation ; Prostaglandin
    Source: Elsevier Journal Backfiles on ScienceDirect 1907 - 2002
    Topics: Biology , Chemistry and Pharmacology , Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Calcified tissue international 54 (1994), S. 208-211 
    ISSN: 1432-0827
    Keywords: DXA ; SPA ; Radius ; Cross-calibration
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine , Physics
    Notes: Abstract Though spinal and femoral measurements are typically preferred for evaluating skeletal density, an abundance of forearm data exists, primarily from single photon absorptiometry (SPA) devices. Most dual X-ray absorptiometry (DXA) scanners are capable of scanning the forearm and provide analysis tools to duplicate conventional SPA measurements. In this study, we have compared the radius density measurements from three commonly available densitometers: a Norland 278 SPA, a Lunar DPX-L, and a Hologic 1000/W. Radius bone mineral density (BMD) on the nondominant forearm was measured in 28 volunteers (21 women and 7 men) aged 24–78, with an average age of 51±17 years. Values were compared and regression relationships derived at corresponding measurement sites. SPA and DXA BMD values were found to be highly correlated (r=0.99) with small standard errors (0.014 g/cm2–0.021 g/cm2), though significant absolute differences were observed at most measurement regions. Correlation slopes ranged from 0.85 to 1.04, with intercepts from 0.01 to 0.08 g/cm2. Using the resultant regression equations, SPA BMD values can be converted to DXA values with an expected error of roughly 3%. DXA BMD can also be interconverted between Lunar and Hologic with a similar expected error. In situations where this level of imprecision is acceptable, patient forearm measurements obtained on different systems can be interconverted.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...