    Springer
    Naunyn-Schmiedeberg's archives of pharmacology 329 (1985), S. 222-226 
    ISSN: 1432-1912
    Keywords: Blood pressure ; Serotonin ; Sympathetic nerve activity ; Cross-circulation ; Central nervous system
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary The possible central regulation of cardiovascular system by serotoninergic neurones was investigated in rats by using a cross-circulated head preparation. Intracarotid injections of serotonin (5-HT, 0.1–10 μg) consistently produced neurally mediated vasodepression in the recipient body. Although intravenous injections of 5-HT (0.1–1 μg) caused similar depressor responses, larger doses (5–10 μg) caused biphasic responses, consisting of vasodepression followed by a sustained pressor response. Despite the biphasic blood pressure responses, sympathetic nerve activity was consistently reduced by the intravenous 5-HT. Bilateral vagotomy abolished the vasodepressor responses to intravenous injections of 5-HT (10 μg) and made the responses purely pressor, but the vasodepressor responses to intracarotid injections of 5-HT (10 μg) were largely unaffected. Following destruction of central noradrenergic neurones by intracerebroventricular injections of 6-hydroxydopamine, the vasodepressor responses to intracarotid 5-HT (1–10 μg), but not to the intravenous 5-HT, were significantly reduced. These results suggest that intravenous injections of 5-HT reduce nerve activity by affecting the reflex mechanism via the vagus nerves. On the other hand, the vasodepression and reduction of the nerve activity by the intracarotid injections appears to be of central origin, and the vasodepression could be mediated via noradrenergic mechanisms in the brain.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1438-8359
    Keywords: Finger arterial blood pressure ; Direct arterial blood pressure ; Omron HEM-802F
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Finger arterial blood pressures determined by a newly developed sphygmomanometer, HEM-802F, were compared with arterial pressure obtained from direct measurement of the radial artery. An excellent correlation was found between the two methods (systolic: r = 0.93, diastolic: r = 0.91), although there was a large variability among individual subjects. The range of differences between them are from +32 to −13 mmHg for systolic and +15 to −25 mmHg for diastolic blood pressure measurement. HEM-802F underestimated systolic pressure (−4.0 mmHg) and overestimated diastolic pressure (+6.7 mmHg), compared with intra-arterial readings. The HEM-802F was useful for the non-invasive arterial pressure monitoring during general anesthesia. (Shigemi K, Takahashi H, Hashimoto S et al.: A comparative study of measurement of arterial blood pressure using HEM-802F and arterial cannulation. J Anesth 4: 91–93, 1990)