Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 18 (1995), S. 685-691 
    ISSN: 0935-6304
    Keywords: On-line LC-GC-MS ; PCBs ; Non-ortho CBs ; Human blood plasma ; Dinitroanilinopropyl modified silica ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A method for the determination of non-, mono- and di-ortho substituted polychlorinated biphenyls in human blood plasma is presented. The non-ortho CBs are isolated from the bulk of PCBs by HPLC on a dinitroanilino-propyl silica column and collected as a heart-cut fraction that is transferred on-line to GC-MS utilizing concurrent solvent evaporation technique. The on-line coupling serves to lower the limit of determination and to partly automate the sample clean-up. The di- and mono-ortho CBs are analyzed by off-line GC-ECD using two different columns. Sample pre-treatment is performed by extraction with organic solvents and fractionation on silica gel. A high reproducibility and an absolute over-all recovery of approximately 70 % is demonstrated. The method is applied to samples of blood from 5 individuals. All the samples demonstrated a similar relative concentration profile. It was also shown that three CB congeners (CB 126, CB 156 and CB 170) contributed to the major part of the toxic equivalent quantity of the PCB content in the blood.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 15 (1992), S. 131-133 
    ISSN: 0935-6304
    Keywords: Press-fit connectors ; Temperature- and pressure-stable connectors ; Epoxy resin glue ; Metal to fused silica connections ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...