Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Disopyramide  (1)
  • Effective renal plasma flow  (1)
  • Key words Fluticasone propionatei  (1)
  • 1
    ISSN: 1432-1041
    Keywords: Key words Fluticasone propionatei ; HPA-axis; bud esonide ; asthma ; children ; corticosteroids ; systemic effects ; plasma cortisol suppression
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Abstract Objective: To compare the systemic potency of inhaled fluticasone propionate delivered via Diskhaler® (FP-DH), and inhaled budesonide delivered via Turbuhaler® (BUD-TBH) over the clinically recommended dose range using plasma cortisol suppression as a marker for systemic activity. Methods: The systemic potency was examined in a dose-response study in 81 healthy male volunteers. The study was of an open, randomized, parallel-group (four groups) design, where two treatments were given in crossover fashion within each group. FP-DH and BUD-TBH were given b.i.d. for 7 days (14 doses): 100 and 100 μg (group 1); 200 and 200 μg (group 2); 500 and 400 μg (group 3); 1000 and 800 μg (group 4). There was a washout period of 7 days within each treatment group. All doses were administered at 08:00 and 20:00 hours. Multiple plasma cortisol samples were taken every 2 h over 24-h periods prior to randomization (baseline) and during steady state (i.e., the last two dosing intervals). Cortisol suppression was determined by comparing average plasma concentrations of cortisol before and during treatment. Dose-response curves for cortisol suppression were analyzed using multivariate non-linear regression (Hill modeling). Results: Multiple dosing for 7 days with FP-DH and BUD-TBH resulted in dose-dependent cortisol suppression by both drugs, most pronounced at the two highest dose levels. FP-DH-induced suppression was 41% at 500 μg and 86% at 1000 μg b.i.d., while that induced by BUD-TBH was 19% at 400 μg and 47% at 800 μg b.i.d. Statistically significant differences were found when comparing the two steroids at these two dose levels. Doses producing 50% of maximum suppression (ED50) were estimated at 833 μg b.i.d. for BUD-TBH and 479 μg b.i.d. for FP-DH. This gave an estimated relative cortisol suppression over the dose range of 1.74:1 (FP-DH:BUD-TBH). ED50 values, estimated from cortisol concentrations at 08:00 hours (12 h after the last dose), were 1212 μg b.i.d. for BUD-TBH and 527 μg b.i.d. for FP-DH giving a relative cortisol suppression of 2.30:1 (FP-DH:BUD-TBH). Fourteen subjects on the highest FP-DH dose and 3 at the next highest dose had morning plasma cortisol levels below the lower reference limit. No subject taking budesonide, however, had morning plasma cortisol levels below the reference limit. Analysis of the time for return to pretreatment baseline levels showed that cortisol suppression, 12–24 h after the last dose, was statistically significant compared with the baseline for the highest dose of FP-DH but not for any of the BUD-TBH doses. Conclusions: The results of the present study show that FP-DH suppresses plasma cortisol more than BUD-TBH on a equivalent basis with regard to both magnitude and duration.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    European journal of clinical pharmacology 11 (1977), S. 91-99 
    ISSN: 1432-1041
    Keywords: Disopyramide ; plasma concentration ; cardiodepressant drugs ; ventricular arrhythmia ; ventricular tachycardia ; pharmacokinetics
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Summary Ten patients with various heart diseases and ventricular arrhythmia received a single oral dose of disopyramide (DE) 200 mg. The ECG was recorded continuously for about 50 h from 2–4 h before drug administration. A statistically significant reduction in the number of ventricular ectopic beats (VEBs) was seen 1.0–3.5 h after drug intake; the average number of VEBs per 30 min decreased from 317 during the control period to 92 by 1.0–3.5 h after treatment and if one patient who did not respond is excluded, the corresponding figures were 272 and 14, respectively. Consecutive VEBs were seen in seven patients before DE was given and decreased significantly (p〈0.05) 1.5–5.5 h after drug administration. There was no change in the PQ interval, the QRS interval showed a slight increase, whereas the QT interval was prolonged 0.5–4 h after administration of DE. A specific gas chromatographic method was used for DE assay in plasma and urine. Absorption was rapid in all patients. Urinary excretion during the first 48 h after drug intake varied between 35 and 75%. The lowest effective antiarrhythmic concentration estimated in six patients ranged from 1.4 to 7.0 µg/ml. β-Phase half-life in five patients was between 10.3 and 22.1 h.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1619-7089
    Keywords: Technetium 99m mercaptoacetyltriglycine ; Plasma clearance ; Effective renal plasma flow
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Recent studies have shown that technetium 99m mercaptoacetyltriglycine (MAG-3) is a suitable replacement for iodine 131 or 123 hippurate in gammacamera renography. Also, the determination of its clearance is of value, since it correlates well with that of hippurate and thus may be an indirect measure of renal plasma flow. In order to simplify the clearance method we developed formulas for the estimation of plasma clearance of MAG-3 based on a single plasma sample and compared them with the multiple sample method based on 7 plasma samples. The correlation to effective renal plasma flow (ERPF) (according to Tauxe's method, using iodine 123 hippurate), which ranged from 75 to 654 ml/min per 1.73 m2, was determined in these patients. Using the developed regression equations the error of estimate for the simplified clearance method was acceptably low (18–14 ml/min), when the single plasma sample was taken 44–64 min post-injection. Formulas for different sampling times at 44, 48, 52, 56, 60 and 64 min are given, and we recommend 60 min as optimal, with an error of estimate of 15.5 ml/min. The correlation between the MAG-3 clearances and ERPF was high (r = 0.90). Since normal values for MAG-3 clearance are not yet available, transformation to estimated ERPF values by the regression equation (ERPF=1.86 × CMAG-3 + 4.6) could be of clinical value in order to compare it with the normal values for ERPF given in the literature.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...