Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Medical & biological engineering & computing 27 (1989), S. 57-63 
    ISSN: 1741-0444
    Keywords: Adaptive filter ; Electrogastrography ; Noise cancellation ; Respiratory artefact
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Chemistry and Pharmacology , Medicine
    Notes: Abstract Electrogastic measurements are useful for medical research and in clinical diagnosis. The measurements, however, contain very heavy respiratory artefact. Existing conventional frequency-domain filters cannot be used because of the possible overlap of the frequencies of the gastric signals and respiratory artefact. In the paper, the methods of measuring cutaneous and intraluminal gastric signals and reference respiratory signals are described. An adaptive cancellation technique is developed, which is simple and easy to implement for online processing. It is proved by experiments to be very efficient, i.e. the respiratory artefact can be completely cancelled, while the gastric signal component is not affected. Other possible applications in biomedical signal analysis are also discussed.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Medical & biological engineering & computing 28 (1990), S. 531-536 
    ISSN: 1741-0444
    Keywords: Autoregressive moving average modelling ; Electrogastrography ; Gastric motility ; Gastric slow wave ; Spectral analysis
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Chemistry and Pharmacology , Medicine
    Notes: Abstract The recording of the human, gastric myoelectrical activity, by means of cutaneous electrodes is called electrogastrography (EGG). It provides a noninvasive method of studying electrogastric behaviour. The normal frequency of the gastric signal is about 0·05 Hz. However, sudden changes of its frequency have been observed and are generally considered to be related to gastric motility disorders. Thus, spectral analysis, especially online spectral analysis, can serve as a valuable tool for practical purposes. The paper presents a new method of the adaptive spectral analysis of cutaneous electrogastric signals using autoregressive moving average (ARMA) modelling. It is based on an adaptive ARMA filter and provides both time and frequency information of the signal. Its performance is investigated in comparison with the conventional FFT-based periodogram method. Its properties in tracking time-varying instantaneous frequencies are shown. Its applications to the running spectral analysis of cutaneous electrogastric signals are presented. The proposed adaptive ARMA spectral analysis method is easy to implement and is efficient in computations. The results presented in the paper show that this new method provides a better performance and is very useful for the online monitoring of cutaneous electrogastric signals.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Medical & biological engineering & computing 27 (1989), S. 538-542 
    ISSN: 1741-0444
    Keywords: Electrogastrography ; Gastric activity ; Phase shift
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Chemistry and Pharmacology , Medicine
    Notes: Abstract Electrogastric signals have been successfully measured both intraluminally and cutaneously. although it has been claimed by several researchers that the propagation direction of the electrogastric activities cannot be observed from cutaneous recordings, it is the aim of the paper to show that it is feasible. The reason why the propagation direction has never been observed from cutaneous recordings is that the reported methods for the abdominal measurements are not adequate. In the paper it is pointed out that the stomach should be localised before the measurement and the electrodes should be attached along the longitudinal axis of the stomach.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...