Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 13 (1990), S. 649-651 
    ISSN: 0935-6304
    Keywords: Capillary gas chromatography ; Cold on-column injection ; Sample split ; Three-way press-fit device ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 15 (1992), S. 155-159 
    ISSN: 0935-6304
    Keywords: Capillary gas chromatography ; Three-way press-fit device ; Cold on-column injection ; Solvent split ; Early solvent vapor exit ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: In a previous paper we described the possibilities of cold on-column - sample split injection achieved by means of an inexpensive and simple three way press-fit device [1]. The same arrangement is proposed here for cold on-column - solvent split injection in which specific elimination of the solvent, without loss of any other sample components, is achieved by opening the splitting tube (or better, in this case, the early solvent vapor exit) during solvent elution, and then closing it during elution of the sample's other components.Discrimination between solvent and other sample components is achieved by means of a retention gap, a retaining precolumn, and an early vapor exit.The technique enables both selective enrichment of a sample, in order to record satisfactory mass and infrared spectra of minor components, and injection of large volumes (up to 100 μl) of dilute solutions which cannot be concentrated because of component volatility. Details of the assembly and tuning the system are given, together with some examples.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...