Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Journal of neural transmission 48 (1980), S. 137-141 
    ISSN: 1435-1463
    Keywords: Radioimmunoassay ; melatonin
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary A radioimmunoassay for melatonin has been developed and used to measure the level of melatonin of male and post-menopausal female patients coming to operation for benign and malignant conditions. The amount of melatonin in the serum of the females was considerably lower than that in males. No difference could be found between patients suffering from benign and malignant conditions. A patient with a non-parenchymatous pineal tumour had considerably lower levels in the serum at three months after surgery and radiotherapy. A further month later melatonin could not be found in samples of serum taken over a 24-hour period.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Experimental brain research 17 (1973), S. 169-176 
    ISSN: 1432-1106
    Keywords: Spinal cord ; Dorsal horn ; Negative intermediary cord potential ; Field potential
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary Electrical stimulation of the sural, superficial peroneal and plantar nerves in anesthetized cats produces a sequence of potentials in the spinal cord lumbosacral enlargement. The distributions of the spinal cord dorsum negative intermediary potential (N1 wave) and of the associated field potential recorded in depth from the spinal gray matter were mapped. The N1 wave produced by the sural nerve was largest at the junction of the S1 and L7 segments, whereas that evoked by the other two nerves was maximum in L6 and L7. The field potentials recorded in depth also showed a differential distribution. The maximum negativity during phase 2, corresponding to the N1 cord dorsum potential, was found to lie laterally in the dorsal horn when the sural nerve was stimulated, but medially when the plantar nerve was activated. The superficial peroneal nerve produced its largest negative field potential in the central region of the dorsal horn. The negative field potentials from the sural and superficial peroneal nerves were not as well separated spatially from each other as they were from the potential evoked by the plantar nerve.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...