Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1437-160X
    Keywords: Immune complexes ; Immunoglobulin isotypes ; Rheumatoid arthritis ; Flow cytometry
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary The immunoglobulin (Ig) heavy chain isotype composition of intra-articular and circulating immune complexes (ICs) were determined by a Raji cell flow cytometric assay in paired serum and synovial fluid samples from 15 patients with rheumatoid arthritis (RA) and 15 patients with other articular diseases (osteoarthritis, ankylosing spondylitis, gout, psoriatic arthritis, Reiter's discase). ICs were most prevalent in synovial fluid samples of patients with RA but were infrequently detected in serum and synovial fluid samples from the non-RA patients. ICs in patients with RA were heterogeneous both in the prevalence of Ig subclasses identified and in the distribution of the respective Ig isotypes within the complexes. Furthermore, differences were observed in the Ig isotype composition of ICs in paired serum and synovial fluid samples in dicating that circulating ICs may not always arise simply by spill-over from articular sites. The possible mechanisms for IC formation in RA are discussed with reference to four patients who displayed features of extra-articular disease.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Medical & biological engineering & computing 28 (1990), S. B29 
    ISSN: 1741-0444
    Keywords: Bias ; Exploratory graphical analysis ; Imprecision ; ISE ; ISFET ; Outliers ; Performance evaluation ; Resistant regression ; Weighted regression ; Whole blood
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Chemistry and Pharmacology , Medicine
    Notes: Abstract Performance evaluations of ion-selective field-effect transistors (ISFETs) have been carried out using both quality-control materials and whole arterial blood samples. Comparison of the results from these evaluations suggests that the whole blood evaluation may be more useful when assessing the value of particular sensors for clinical applications. The effect of outliers on the imprecision estimates is demonstrated for ISFETs and ISEs, both graphically and in the calculation of the estimates with an without the outliers present. Estimates of constant and proportional bias, against an alternative sensor, determined from the intercept and slope of the linear regression vary according to the regression method used. The bias estimates obtained for the K+ISFET against the Radiometer KNA1 using ordinary least squares regression are compared with the Deming/Mandel method and the three-group resistant line method of Tukey. The Thorn EMI ISFETs are demonstrated to have acceptable imprecision and only a small bias compared with direct ISE instruments for whole blood assay and can be considered suitable for incorporation into clinical instrumentation.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...