Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1437-160X
    Keywords: HLA-B27 ; Microlymphocytotoxicity test ; Enzyme immunoassay ; Flow cytometry ; Rheumatology
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Typing for HLA-B27 is routinely performed in patients with seronegative spondarthritides. Besides the microlymphocytotoxic test (MLCT), other serological techniques have been developed such as enzyme immunoassays (EIA) using serum or plasma as a source for the determination of soluble HLA-B27 (sHLA-B27) and flow cytometric (FC) methods. The aim of the present study was to check the accuracy and reliability of the EIA for sHLA-B27 in comparison to the MLCT using antibodies against HLA-B27 and cross-reacting specificities (CRS), as well as an FC method and a molecular biological method. Any discrepant results should be typed with the MLCT using a complete panel of anti-HLA-class I antibodies, with FC and with a molecular biological technique. The EIA should also be repeated in those patients, using serum and plasma from a new venipuncture. In 81 patients with rheumatic disorders, the EIA and the MLCT using antibodies against HLA-B27 and CRS were performed. Based on the MLCT with a complete panel of anti-HLA-class I antibodies as a standard, discrepant test results were obtained for 9 out of 81 patients with the MLCT using antibodies against HLA-B27 and CRS and with the EIA. The following wrong results occurred: in the MLCT with anti-HLA-B27 and CRS, there were two false-negative results; in the EIA there were four false-negative and one false-positive results: one sample was undeterminable. In comparison with the MLCT, including the complete panel of HLA-class I antibodies, as well as with a molecular biological technique, typing with FC showed a complete concordance. Our investigations demonstrated that for routine typing for HLA-B27 the MLCT cannot be replaced by EIA because of a significant number of mistypings. The MLCT performed only with antibodies against HLA-B27 and CRS may also lead to typing errors. No errors were detected using flow cytometry. If only serological methods can be performed in a laboratory a combination of flow cytometry and MLCT could therefore enhance the safety of HLA-B27 typing.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...