Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Medical & biological engineering & computing 22 (1984), S. 309-316 
    ISSN: 1741-0444
    Keywords: Capacitive transducer ; Error analysis ; Foot force ; Gait analysis
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Chemistry and Pharmacology , Medicine
    Notes: Abstract A capacitive transducer is developed which continuously measures the vertical component of foot forces during walking. The transducer is shaped like an insole and consists of two subtransducer units, the front and rear. The outputs of the two units are summed to give the total force exerted by the foot. Each unit has a multilayered structure. The basic layer is a 2 mm Neoprene sponge sheet sandwiched by two 50 μm copper foils. They as a whole form a capacitor. The other two layers are a driving shield and static shield, which minimise the effect of stray capacitance and power-line noise, respectively. The transducer is thin (3·8 mm), light (90 g) and flexible and so does not hinder the natural gait pattern. It can be attached to the sale of the shoe easily by elastic bands and Velcro straps. The accuracy of the transducer is well within ±10 per cent of the full scale. An error analysis is made to clarify the change in sensitivity owing to a localised foad. The results are used to compensate for the inherent nonlinearity of the transducer units.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Medical & biological engineering & computing 22 (1984), S. 70-76 
    ISSN: 1741-0444
    Keywords: Correlation analysis ; Gait analysis ; Gait evaluation ; Pathological gait ; Quantitative indices
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Chemistry and Pharmacology , Medicine
    Notes: Abstract Although various methods have been proposed for quantitative evaluation of pathological gait, they are not yet widely used as routine clinical tools. The reasons are that measuring systems are too expensive and complicated and that the validity of the methods has not been fully examined in a statistical manner. In this paper, the validity of a new evaluation method based on a simple foot-force measuring device is investigated in terms of the correlation between quantitative indices and visually-rated grades. Forty-eight hemiparetic patients secondary to cerebral vascular accident walked on a 15 m straight level floor. Four people independently evaluated each subject in eight gait characteristics or items on a scale of 1–4 grades on the basis of visual inspection. These items include symmetry, variation, fluctuation, and dependence on the cane. At the same time, the vertical ground-reaction forces exerted on the right and left feet and on the cane were measured, and then quantitative indices representing these eight items were derived. All but one index shows a reasonably good correlation with the mean of the grades of the four observers. Thus, the feasibility of these indices is demonstrated. Statistical analysis also reveals several problems inherent in visual rating, such as inconsistency in the interpretation of evaluation criteria among observers, and a degradation of the independence of items owing to the observer’s subjectivity.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...