Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1619-7089
    Keywords: Key words: Pulmonary embolism ; Lung scintigraphy ; Thrombosis ; D-dimer
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract. D-dimer assay (DDA), measuring fibrin degradation products, was compared with lung scintigraphy (LS) in a prospective unselected series of 83 consecutive patients referred owing to suspicion of pulmonary embolism (PE). This patient series was also used to compare several methods of performing and interpreting LS images. The final diagnosis was established independently by a separate panel with all available information except for the result of DDA. D-dimer was determined by ELISA (threshold value 500 ng/ml). LS, including perfusion (.Q) and pseudo-ventilation (Technegas) (.V), was classified according to PIOPED, (1) immediately by the physician on duty, and (2) retrospectively by a blinded panel. A positive (19) or negative (61) diagnosis of PE was achieved in 80 patients, the prevalence of PE being 24%. Only one false-negative was noted on DDA (sensitivity=95%) but there were 42 false-positives (specificity=31%), resulting in a positive predictive value of 30% and a negative predictive value of 95%. Emergency and retrospective interpretations of LS were close (kappa=0.4). In a minority of patients, PE may be excluded with reasonable certainty if DDA is normal, resulting in a significant saving in terms of time and money.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1619-7089
    Keywords: Pulmonary embolism ; Lung scintigraphy ; Thrombosis ; D-dimer
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract D-dimer assay (DDA), measuring fibrin degradation products, was compared with lung scintigraphy (LS) in a prospective unselected series of 83 consecutive patients referred owing to suspicion of pulmonary embolism (PE). This patient series was also used to compare several methods of performing and interpreting LS images. The final diagnosis was established independently by a separate panel with all available information except for the result of DDA. D-dimer was determined by ELISA (threshold value 500 ng/ml). LS, including perfusion (Q) and pseudo-ventilation (Technegas) (V), was classified according to PIOPED, (1) immediately by the physician on duty, and (2) retrospectively by a blinded panel. A positive (19) or negative (61) diagnosis of PE was achieved in 80 patients, the prevalence of PE being 24%. Only one false-negative was noted on DDA (sensitivity=95%) but there were 42 false-positives (specificity=31%), resulting in a positive predictive value of 30% and a negative predictive value of 95%. Emergency and retrospective interpretations of LS were close (kappa=0.4). In a minority of patients, PE may be excluded with reasonable certainty if DDA is normal, resulting in a significant saving in terms of time and money.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    European journal of nuclear medicine 13 (1987), S. 439-442 
    ISSN: 1619-7089
    Keywords: Emission tomography ; Image distortion ; Gamma camera
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Image quality in single photon emission computed tomography (SPECT) using a rotating gamma camera is dependent on the time course of the tracer in the field of view. If acquisition times are slow comapred to the tracer turnover, artifacts may occur in the reconstructed images. The properties of such artifacts were studied by computer simulation. Experimental projection data of point sources, cylindrical phantoms, and an anatomically realistic brain phantom were altered by sequentially weighting the projections with a function that varied exponentially or linearly with time. The observed distortion in the reconstructed images could be related to the ratio between the object activity variation and the camera rotation time. If the tracer concentration changed less than a factor of two during one camera rotation then little image distortion was visible although quantitatively the resolution was degraded. If the object's activity variation with time is fast enough to produce noticeable distortion, the artifacts can be reduced by performing multiple, rapid, camera rotations, instead of one rotation, for the same total acquisition time. The proposed procedure is computer storage space intensive and takes longer to produce the transaxial images, but improves image quality.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...