Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 1 (1978), S. 143-148 
    ISSN: 0935-6304
    Keywords: Gas Chromatography ; Capillary glass ; Tailor-made by graphitized carbon black precoating ; Application to pesticides, terpenes, aromatic hydrocarbons, free fatty acids ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The performance of graphitized glass capillary columns obtained by precoating the inner glass walls with graphitized carbon black has been evaluated. It has been shown that according to the amount of stationary phase coated such columns can operate in gas-liquid-solid chromatography and in gas-liquid chromatography so that tailor-made columns for specific separations can be prepared. The versatility of these columns is shown in the separation of various mixtures (terpenes, pesticides, isomeric species and others) of analytical importance.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 0935-6304
    Keywords: Capillary GC ; Nitrofluoranthenes ; Nitropyrenes ; Diesel exhaust ; Urban particulate matter ; Industrial emission ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A 15 m DB-17 fused-silica capillary column has been used to achieve the separation of all mononitrofluorarthene and mononitropyrene isomers. Linear Retention Indices and Relative Retention times for each component have been measured and the values were compared with those observed on DB-5 columns, commonly used for this separation. Increased polarity of the liquid phase results in better separation of some key isomeric pairs (such as 2-, 3-nitrofluoranthene and 1-nitropyrene, 8-nitrofluoranthene), difficult to resolve on DB-5 columns. Practical applications are reported. They include the analysis of extracts from emission samples (diesel exhaust and particles emitted by a factory manufacturing carbon electrodes) as well as atmospheric dust sampled in a urban area under different conditions.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗