  • 1
    ISSN: 1432-0428
    Keywords: Glucose sensor ; enzyme electrode ; biosensor ; glucose oxidase ; ferrocene ; diabetes mellitus
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary Miniature, amperometric glucose sensors were constructed for implantation in the subcutaneous tissue of normal and insulin-dependent diabetic subjects. To minimise dependence on fluctuating tissue oxygen tension, we employed the technology of mediated electron transfer, with 1,1′-dimethylferrocene acting as the redox shuttle between immobilized glucose oxidase and a platinum base electrode. In 6 normal subjects, the subcutaneous sensor responses mirrored the simultaneously-measured changes in blood glucose concentration after a 75 g oral glucose load and after intravenous injection of 0.15 U/kg short-acting insulin, though increases and decreases in the sensor output were slower than the glycaemic changes. The mean peak delay in sensor response after the oral glucose was 40 min (range 0–45 min) and the delay in the hypoglycaemic nadir was 4 min (range 0–15 min). In 5 insulin-dependent diabetic subjects, spontaneous and induced hypoglycaemia was detectable by the implanted sensor. In addition, marked and frequent oscillations in the sensor current occurred in several normal and diabetic individuals as the blood glucose fell below about 1.9 mmol/l. These oscillations were present in a diabetic subject who had lost adrenergic warning symptoms to hypoglycaemia. Continuous metabolic monitoring in diabetes, particularly the detection of hypoglycaemia, may be possible with implanted sensors based on this technology.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Acta diabetologica 30 (1993), S. 143-148 
    ISSN: 1432-5233
    Keywords: Biosensor ; Enzyme electrode ; Glucose sensor
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Glucose sensors based on immobilized glucose oxidase and hydrogen peroxide detection at a platinum base electrode were constructed and studied before, during and after implantation into the subcutaneous tissue of 11 non-diabetic subjects. A 75-g oral glucose load was given to elevate the blood glucose concentration. Seven of 14 sensors responded to the oral glucose administration with an increase in current and the output of the remainder was unchanged by the glucose load. Apparent subcutaneous glucose levels calculated from the pre-implantation calibration were a mean 58% of the plasma glucose values at baseline. A two-point in vivo calibration using paired current and glucose readings at baseline and at the maximum glucose and current after glucose ingestion showed a significantly reduced sensitivity in vivo compared with pre-implantation values (mean±SEM 52±21.5 vs 369±127 pA/mmol−1 per litre,P=0.003). Recalibration of the subcutaneous glucose concentrations using the in vivo calibration sensitivity and extrapolated background current (I o) gave values similar to those in plasma. The sensitivity of five sensors recalibrated in vitro after explantation was also reduced compared with pre-implantation levels and not significantly different from the in vivo characteristics. Responding and nonresponding sensors did not differ with respect to preimplantationI o, sensitivity or response time. However, provisional examination of some explanted sensors by scanning electron microscopy showed coating by cellular and other amorphous material in the non-functioning electrodes. We conclude that the sensitivity of glucose sensors of this design is markedly reduced, sometimes to zero, on implantation in the subcutaneous tissue of humans. Though several factors may contribute to this effect, a likely explanation is coating of or interaction with the sensor by components of the biological matrix.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...