Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Documenta ophthalmologica 78 (1991), S. 183-187 
    ISSN: 1573-2622
    Keywords: Hyperthermia ; near-infrared irradiation ; xenon arch photocoagulator ; experimental melanoma
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract The technique of near-infrared irradiation to obtain tumour necrosis in experimental pigmented melanomas is described. The xenon arch photocoagulator was modified and adapted for hyperthermia treatment. The adaptations included: filtering the light and changing the electronics, the aiming beam and the diameter of the beam.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Documenta ophthalmologica 73 (1989), S. 249-254 
    ISSN: 1573-2622
    Keywords: Graves ; ophthalmopathy ; corneal epithelium ; permeability ; fluorophotometry
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract The function of the corneal epithelium was evaluated in 30 patients with Graves' ophthalmopathy in whom no signs of corneal disease were observed. This function was evaluated by determining the permeability values of the corneal epithelium for fluorescein using fluorophotometry. The permeability values of the patients were compared with those of 46 healthy individuals. A significant increase in the permeability values was seen in 11 (37%) patients and in two (4%) controls (p 〈 0.05). The difference in the mean permeability values between patients en controls was statistically significant (0.053 nm/sec. ± 0.043 SD and 0.038nm/sec. ± 0.017 SD, respectively, p 〈 0.05). No relation was found between the permeability alues of the corneal epithelium and the NOSPECS classification or the duration of the disease. There was a tendency for increased permeability values in patients having an exophthalmos larger than 20mm. (correl. coeff. = +0.3, p 〈 0.05).
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗