    European journal of applied physiology 50 (1982), S. 13-21 
    ISSN: 1439-6327
    Keywords: Plasma volume ; Haematocrit ; Haemoglobin ; F-cell ratio
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary The effects of alterations in the F-cell ratio (i.e., the ratio of the whole body haematocrit to the peripheral haematocrit) on calculations of relative (percentage) change in plasma volume have been considered. Errors introduced by failing to correct the measured haematocrit for an assumed value for the F-cell ratio are small, and are negligible compared with the random measurement errors. Errors introduced by a change in the value of the F-cell ratio from some control value to a new value during an experimental procedure (such as exercise or exposure to heat stress) are large, and could lead to gross misrepresentations of the direction and magnitude of any induced change in intravascular volume, and of solute concentration changes assumed to reflect only loss or gain of fluid by the intravascular space.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    European journal of applied physiology 55 (1986), S. 187-194 
    ISSN: 1439-6327
    Keywords: Blood volume ; protein ; Blood pressure ; Heart rate ; Head-up tilt
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary Experiments were undertaken to determine the effects of hydration status on a) orthostatic responses, and on b), relative changes in intravascular volume and protein content, during 70
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    European journal of applied physiology 56 (1987), S. 673-678 
    ISSN: 1439-6327
    Keywords: Blood volume ; Plasma volume ; Specific gravity ; Capillary filtration ; Ultrafiltrate ; Albumin ; Globulins ; Haematocrit
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary High precision blood and plasma densitometry was used to measure transvascular fluid shifts during water immersion to the neck. Six men (28–49 years) undertook 30 min of standing immersion in water at 35.0±0.2
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Springer
    European journal of applied physiology 55 (1986), S. 367-373 
    ISSN: 1439-6327
    Keywords: Carotid baroreceptors ; Central blood volume ; Heart rate ; Blood pressure
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary Altered baroreflex function may contribute to the cardiovascular changes associated with weightlessness. Since central blood volume (CBV) increases during simulated weightlessness, we have examined the possibility that acute changes in CBV may modify baroreceptor function. We used graded head-up tilt (HUT) and head-down tilt (HDT) to induce changes in CBV, and neck suction to stimulte carotid baroreceptors, in 6 subjects. The increase in pulse interval induced by a negative pressure of 8.2 kPa (62 mm Hg) imposed for 10 s while supine was compared with the increase while tilted for 8 min at ± 15