Bibliothek

Sprache
Bevorzugter Suchindex
Ergebnisse pro Seite
Sortieren nach
Sortierung
Anzahl gespeicherter Suchen in der Suchhistorie
E-Mail-Adresse
Voreingestelltes Exportformat
Voreingestellte Zeichencodierung für Export
Anordnung der Filter
Maximale Anzahl angezeigter Filter
Autovervollständigung
Feed-Format
Anzahl der Ergebnisse pro Feed
feed icon rss

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
Filter
  • Hand biomechanics  (1)
  • 1
    ISSN: 1573-9686
    Schlagwort(e): Medical imaging ; Magnetic resonance imaging ; Biomechanics ; Tendon moment arm ; Functional neuromuscular stimulation ; Tendon transfer surgery ; Hand biomechanics
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin , Technik allgemein
    Notizen: Abstract New three-dimensional (3D) magnetic resonance imaging (MRI) methods for measuring the tendon moment arm were created and were evaluated on the tendon moment arm of the flexor digitorum profundus at the third metacarpophalangeal joint. Using an open magnet MRI system and a hand holder, a series of static images were acquired at four joint angles and analyzed using specially created computer programs. Three methods were evaluated: (1) a 3D tendon excursion method that extended the method of Landsmeer; (2) a 3D geometric method whereby the moment arm was the perpendicular distance between the joint axis of rotation and the tendon path, and (3) a two-dimensional (2D) geometric method whereby single image slices were analyzed. Repeating the imaging and measurement processes, the 3D tendon excursion method was more reproducible (6% variation) than the 3D geometric method (12%), and both were much more reproducible than the 2D geometric method (27%). By having three operators analyze a single set of image data, we found that the precision of the 3D tendon excursion method was much less affected by segmentation error than the 3D geometric method. With the 3D imaging methods, tendon bowstringing and a displacement of the joint center of rotation toward the dorsal side of the hand were evident, leading to as much as a 60% increase in moment arm with joint flexion. Because of the dependence on flexion and variation between subjects, we recommend patient-specific measurements for target applications in functional neuromuscular stimulation interventions and tendon transfer surgery. © 1999 Biomedical Engineering Society. PAC99: 8761Pk, 8719Rr, 0705Pj
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...