Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1432-2161
    Keywords: Hip arthroplasty ; Leg length inequality ; Weight-bearing radiography ; Leg length measurement ; Hip arthritis
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Alteration of the length of the lower limb was measured in 39 patients undergoing total hip replacement. Radiographs were taken in the erect posture prior to operation and 6 months postoperatively. The inequality of limb length was measured by the difference between the height of the vertices of the femoral heads and by the difference between the lowest points of the ischial tuberosities. The change of the length was measured intraoperatively as the difference observed between two reference points: one above the acetabulum and the other on the proximal femur. Good correlation was obtained between the change of the limb length made intraoperatively and the change in the limb length using the ischial tuberosities as reference points; no correlation was observed when the vertices of the femoral heads were the reference points. Inequality of limb length can be radiologically determined before and after total hip arthroplasty. Femoral and prosthetic heads are not good reference points for measurement. The difference in the height of the ischial tuberosities demonstrates inequality of limb functional length as it reflects the tilting of the pelvis.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...