Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Hyaluronic acid  (1)
  • Method and apparatus for CT  (1)
  • 1
    ISSN: 1434-0879
    Keywords: Hyaluronic acid ; Urethral ; Guided tissue regeneration ; Rabbits
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract We investigated the outcome of reconstructive surgery of the urethra through guides composed of a novel biodegradable and highly biocompatible polymer, Hyaff-11. A tract of about 1.5 cm of the rabbit pendulous urethra was totally resected and replaced by a Hyaff-11 tubular graft. Eleven animals were analysed at each of the time points ranging from 7 days to 4 weeks following surgery. Histological and radiological evaluation showed a satisfactory remodelling of the neo-urethra around the implant. The regenerated connective tissue connected both urethral stumps within the first 7 days. On postoperative week 3, the Hyaff-11 guide had disappeared. At the 4-week time point the retrograde urethrogram showed a good distensibility of the neourethra. The regenerated stroma consisted of fibroblastic cells, and collagenous and elastic fibres. The neo-epithelium was pluristratified and exhibited cells of the cuboidal type.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Neuroradiology 22 (1981), S. 23-25 
    ISSN: 1432-1920
    Keywords: Image reconstruction ; Method and apparatus for CT ; Spinal examination ; High resolution CT
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary The diagnostic features of CT images of the spine are constantly influenced by some limitations of the method because of the peculiar configuration of the human spine. Recent generations of CT scanners greatly improve the results but with the second generation (Acta 0200 FS Pfizer Scanner) we have been able to develop a modified scan reconstruction method to maintain the quality of our spinal images, thanks to the very flexible software of our CT scanner.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...