Library

Language
Preferred search index
Number of Hits per Page
Default Sort Criterion
Default Sort Ordering
Size of Search History
Default Email Address
Default Export Format
Default Export Encoding
Facet list arrangement
Maximum number of values per filter
Auto Completion
Feed Format
Maximum Number of Items per Feed
feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1432-0428
    Keywords: Peritoneal ; rat ; glucose kinetics ; closed-loop insulin therapy ; glucose sensor ; bioartificial pancreas
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary Peritoneal glucose kinetics were evaluated in the anaesthetized rat, to assess whether the peritoneal cavity would be a suitable site for the implantation of membrane-protected islets of Langerhans (bioartificial pancreas) or the glucose sensor of an artificial B cell. Glucose was measured in peritoneal fluid samples aspirated by needle puncture. Basal peritoneal and blood glucose concentrations were identical in 16 h fasted (n=4) and non fasted (n=3) animals. After 10 min of an i.v. glucose infusion (n=15) the increment in peritoneal glucose concentration was 63±3% of the increment in blood glucose concentration and both values were significantly correlated (r=0.92; p〈0.001). After 10 min of glucose clamping (12.6±0.8 mmol/l), the increment in peritoneal glucose concentration was 69±3% (n=5; p〈0.05) of the increment in blood glucose concentration. In three additional experiments it was 93±3% of the increment in blood glucose concentration (NS), after 30 min of glucose clamping (8.0±0.5 mmol/l). Peritoneal glucose concentration monitored by a glucose sensor: (a) followed blood glucose sluggishly during a glucose clamp (n=5), confirming the data shown above, (b) followed blood glucose with a 5 min delay and reached the same plateau after the intravenous injection of 1U insulin (n=3; NS). We conclude that peritoneal glucose reflects blood glucose at basal state and during variations of glycaemia, nevertheless, presenting heterogeneous kinetics. These kinetics might be appropriate for a bioartificial pancreas but not for an in vivo calibration procedure, of a peritoneally implanted glucose sensor.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1432-0428
    Keywords: Keywords Genetics ; MODY ; glucokinase gene ; HNF-1α ; HNF-4α ; HNF-1β ; IPF1 ; transcription factors
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary Maturity-onset diabetes of the young (MODY) is a heterogeneous subtype of non-insulin-dependent diabetes mellitus characterised by early onset, autosomal dominant inheritance and a primary defect in insulin secretion. To date five MODY genes have been identified: hepatocyte nuclear factor-4 alpha (HNF-4 α/MODY1/TCF14) on chromosome 20 q, glucokinase (GCK/MODY2) on chromosome 7 p, hepatocyte nuclear factor-1 alpha (HNF-1 α/MODY3/TCF1) on chromosome 12 q, insulin promoter factor-1 (IPF1/MODY4) on chromosome 13 q and hepatocyte nuclear factor-1 beta (HNF-1 β/MODY5/TCF2) on chromosome 17cen-q. We have screened the HNF-4 α, HNF-1 α and HNF-1 β genes in members of 18 MODY kindreds who tested negative for glucokinase mutations. Five missense (G31D, R159W, A161T, R200W, R271W), one substitution at the splice donor site of intron 5 (IVS5nt + 2T→A) and one deletion mutation (P379fsdelT) were found in the HNF-1 α gene, but no MODY-associated mutations were found in the HNF-4 α and HNF-1 β genes. Of 67 French MODY families that we have now studied, 42 (63 %) have mutations in the glucokinase gene, 14 (21 %) have mutations in the HNF-1 α gene, and 11 (16 %) have no mutations in the HNF-4 α, IPF1 and HNF-1 β genes. Eleven families do not have mutations in the five known MODY genes suggesting that there is at least one additionnal locus that can cause MODY. [Diabetologia (1998) 41: 1017–1023]
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...