Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Key words: VATS — Hand suture — Pacemaker implantation  (1)
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Surgical endoscopy and other interventional techniques 11 (1997), S. 1167-1170 
    ISSN: 1432-2218
    Keywords: Key words: VATS — Hand suture — Pacemaker implantation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Background: In neonates and infants epicardial stimulation may be preferred to endocardial stimulation because of growth-associated lead problems and the risk of vascular complications associated with transvenous electrodes. This study analyzes the feasibility of atrioventricular implantation of a new epicardial lead using the video-assisted thoracic surgical (VATS) technique in an animal model. Methods: Bipolar steroid-eluting epicardial leads were implanted in seven young white pigs. In five animals bipolar atrial and ventricular pacing leads (n= 10) were inserted and fixed by the VATS technique, while two animals served as controls and underwent implantation through anterolateral thoracotomy. Surgical feasibility, pacing, and sensing thresholds of the leads as well as hemodynamic parameters during pacing were studied. Histological changes beneath the electrodes were evaluated 1 week after the implantation. Results: All animals survived the pacemaker lead implantation. One animal which underwent thoracotomy died because of irreversible ventricular fibrillation induced by rapid ventricular pacing. One animal in the VATS group exhibited intraoperative herniation of the heart through the pericardial window. All animals with left-sided VATS implantations demonstrated good individual pacing and sensing threshold values. The mean cardiac output was 1.6 times higher during AAI-mode pacing as compared to VVI-mode pacing at a heart rate of 140/min. One animal died postoperatively due to respiratory failure. No displacements of the pacemaker leads were observed in the survivors. Conclusion: While VATS-guided implantation of epicardial, atrial, and ventricular leads is feasible, technical improvements of the system are mandatory for safe clinical application.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...