Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1432-1920
    Keywords: Key words Vertebral artery ; Angiography ; Vertebrobasilar insufficiency
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Pathology at the origin of the vertebral artery may be the cause of incapacitating vertebrobasilar insufficiency (VBI). Preoperative diagnosis is made primarily on angiographic criteria. We compared intraoperative and angiographic findings in 30 patients and found important diagnostic discrepancies in patients with a caudal, ventral or dorsal origin of the vertebral artery. In their angiograms, vessel superimposition led us to over look 3 ostial stenoses and 10 stenoses due to kinking. Angiographic assessment of patients with VBI can be difficult. Adequate visualisation of the origin of the vertebral artery is mandatory for accurate diagnosis.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1432-1084
    Keywords: Key words: Brain ; MR ; Fast sequences ; FSE ; GRASE
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract. The aim of our study was to compare gradient-spin-echo (GRASE) to fast-spin-echo (FSE) sequences for fast T2-weighted MR imaging of the brain. Thirty-one patients with high-signal-intensity lesions on T2-weighted images were examined on a 1.5-T MR system. The FSE and GRASE sequences with identical sequence parameters were obtained and compared side by side. Image assessment criteria included lesion conspicuity, contrast between different types of normal tissue, and image artifacts. In addition, signal-to-noise, contrast-to-noise, and contrast ratios and were determined. The FSE technique demonstrated more lesions than GRASE and with generally better conspicuity. Smaller lesions in particular were better demonstrated on FSE because of lower image noise and slightly weaker image artifacts. Gray–white differentiation was better on FSE. Ferritin and hemosiderin depositions appeared darker on GRASE, which resulted in better contrast. Fatty tissue was less bright on GRASE. With current standard hardware equipment, the FSE technique seems preferable to GRASE for fast T2-weighted routine MR imaging of the brain. For the assessment of hemosiderin or ferritin depositions, GRASE might be considered.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...