Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Knudsen effusion method  (1)
  • double melting peak  (1)
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Journal of thermal analysis and calorimetry 49 (1997), S. 343-349 
    ISSN: 1572-8943
    Keywords: double melting peak ; DSC ; fiber ; polyethylene
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Abstract The multiple melting peaks observed on differential scanning calorimetry (DSC) of ultrahigh molar-mass polyethylene fibers (UHMMPE) are analyzed as a function of sample mass. Using modern DSC capable of recognizing single fibers of microgram size, it is shown that the multiple peaks are in part or completely due to sample packing. Loosely packed fibers fill the entire volume of the pan with rather large thermal resistance to heat flow. On melting, the fibers contract and flow to collect ultimately at the bottom of the pan. This process seems to be able to cause an artifact of multistage melting dependent on the properties of the fibers. A method is proposed to greatly reduce, or even eliminate, errors of this type. The crucial elements of the analysis of melting behavior and melting temperature are decreasing the sample size and packing the individual fibers in a proper geometry, or to introduce inert media to enhance heat transport.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Journal of thermal analysis and calorimetry 53 (1998), S. 431-439 
    ISSN: 1572-8943
    Keywords: Knudsen effusion method ; pressure DSC ; steel ball method ; vapor pressure determination
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Abstract A new pressure DSC module (Mettler DSC27HP) and its abilities for vapor pressure determination in the range of subambient pressure to 7 MPa are presented. To compare the new to an established method, vapor pressures of caffeine, naphthalene and o-phenacetin have been determined both by pressure DSC and the Knudsen effusion cell method. These results, including the derived heats of evaporation and heats of sublimation, are compared to literature values.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...