Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    European journal of applied physiology 58 (1988), S. 228-232 
    ISSN: 1439-6327
    Keywords: Biceps muscle ; Muscle fatigue ; Electromyography
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary The aim of the study was to investigate the recovery of the maxium voluntary contraction force (MVC), the endurance time and electromyographical (EMG) parameters following exhaustive dynamic exercise of the m. biceps brachii. EMG recordings were made in ten healthy subjects using bipolar surface electrodes placed over the common belly of the left arm biceps muscle. Up to 25 h post-exercise, the maximum contraction force and the EMG signal were recorded alternately at regular intervals. The EMG signal was recorded during 30-s contractions at 40% of the pre-fatigued MVC. Four hours and 25 h post-exercise, the endurance time of a 40% pre-fatigued MVC was recorded. Up to 25 h after the exercise the maximum contraction force, the endurance time and the EMG parameters were significantly different from the pre-exercise values. Nine out of ten subjects complained that muscle soreness had developed. Thus, long-lasting changes are found after exhaustive dynamic exercise, not only in the MVC and the muscle's endurance capacity, but also in the EMG signal.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    European journal of applied physiology 63 (1991), S. 444-448 
    ISSN: 1439-6327
    Keywords: Muscle fatigue ; Recovery ; Surface electromyogram ; Biceps muscle
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary Five men performed submaximal isometric, concentric or eccentric contractions until exhaustion with the left arm elbow flexors at respectively 50%, 40% and 40% of the prefatigued maximal voluntary contraction force (MVC). Subsequently, and at regular intervals, the surface electromyogram (EMG) during 30-s isometric test contractions at 40% of the prefatigued MVC and the muscle performance parameters (MVC and the endurance time of an isometric endurance test at 40% prefatigued MVC) were recorded. Large differences in the surface EMG response were found after isometric or concentric exercise on the one hand and eccentric exercise on the other. Eccentric exercise evoked in two of the three EMG parameters [the EMG amplitude (root mean square) and the rate of shift of the EMG mean power frequency (MPF)] the greatest (P〈0.001) and longest lasting (up to 7 days) response. The EMG response after isometric or concentric exercise was smaller and of shorter duration (1–2 days). The third EMG parameter, the initial MPF, had already returned to its prefatigued value at the time of the first measurement, 0.75 h after exercise. The responses of EMG amplitude and of rate of MPF shift were similar to the responses observed in the muscle performance parameters (MVC and the endurance time). Complaints of muscle soreness were most frequent and severe after the eccentric contractions. Thus, eccentric exercise evoked the greatest and longest lasting response both in the surface EMG signal and in the muscle performance parameters.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    European journal of applied physiology 50 (1982), S. 23-33 
    ISSN: 1439-6327
    Keywords: Muscular fatigue ; Isometric contraction ; M. biceps brachii ; EMG power spectrum shift ; Muscle fibre action potential conduction velocity
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary Muscular fatigue was studied in the human m. biceps brachii by contracting the muscle as long as possible at 50% of maximum voluntary strength. For 8 subjects changes in the muscle fibre action potential conduction velocity could successfully be measured using the cross-correlation technique between two surface EMG signals. Shifts in the EMG power spectrum were quantified using the mean power frequency (MPF) of the EMG power spectral density function. During fatigue the EMG power spectrum gradually shifted to lower frequencies. The mean value and standard deviation of the MPF value decreased from (115±20) Hz at the beginning of the experiment to (60±18) Hz at the end. For 4 of the 8 subjects the decrease in MPF value was accompanied by a substantial decrease in conduction velocity (mean decrease was 33% of the initial velocity value). For the other 4 subjects, despite the great MPF changes, there was hardly any change in conduction velocity (mean decrease was 3%). The present study shows that great EMG power spectral shifts during muscular fatigue may occur without a concomitant change in muscle fibre action potential conduction velocity.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...