Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Journal of clinical monitoring and computing 4 (1988), S. 16-20 
    ISSN: 1573-2614
    Keywords: Complications: hypoxemia ; Monitoring: oxygen ; Measurement techniques: pulse oximetry ; Anesthesia: post-operative period
    Source: Springer Online Journal Archives 1860-2000
    Topics: Computer Science , Medicine
    Notes: Abstract Pulse oximetry was used to assess the prevalence of hypoxemia (arterial oxygen saturation of 90% or less) at various times in the immediate postoperative period: five minutes after arrival, 30 minutes later, and just before discharge. Among 149 inpatients studied, one or more hypoxemic measurements were made in 21 (14%) during their postoperative course. Of 92 outpatients, 1 (1%) was found to be hypoxemic. For inpatients, the prevalence of hypoxemia preoperatively, 5 minutes after arrival in recovery, 30 minutes later, and at discharge was 2%, 4%, 6%, and 9%, respectively. Patient factors associated with a significantly higher prevalence of hypoxemia were obesity (22%), body cavity surgical procedures (24%), age over 40 years (18%), American Society of Anesthesiologists physical status (I, 7%; II, 17%; III, 18%; IV, 100%), duration of anesthesia longer than 90 minutes (18%), and intraoperative administration of greater than 1,500 ml of fluid (20%). Unrecognized hypoxemia in postsurgical inpatients with or without these risk factors is common. Therefore routine monitoring of these patients with a pulse oximeter is suggested.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Journal of clinical monitoring and computing 5 (1989), S. 246-249 
    ISSN: 1573-2614
    Keywords: Blood: carboxyhemoglobin ; Oxygen: saturation ; Measurement techniques: pulse oximetry
    Source: Springer Online Journal Archives 1860-2000
    Topics: Computer Science , Medicine
    Notes: Abstract The relationship between arterial oxygen saturation as measured by the pulse oximeter (SpO2) and the fractional arterial oxygen saturation (SaO2) in the presence and absence of carboxyhemoglobin (COHb) has been derived according to the theory of absorption spectroscopy. We find that our theoretically derived correction equation is similar to that found in the technical literature of Nellcor. However, the correction equations presented by Barker and Tremper and the technical literature of Ohmeda differ substantially from our equation when sufficient quantities of reduced hemoglobin are present and the fractional COHb saturation (SaCO) is high. Our approximated equation, derived from the Lambert-Beer law, is SaO2=SpO2(1−0.932 SaCO)+0.032 SaCO. The equation of Barker and Tremper is SaO2=SpO2−0.9 SaCO. The Nellcor equation is SaO2=SpO2(1−SaCO).
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...