Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1435-1528
    Keywords: Mechanical rheometry ; polarimetry ; polystyrene ; segmental orientation ; flow-induced phase separation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Physics
    Notes: Abstract Experiments combining mechanical rheometry with polarimetry (birefringence and scattering dichroism) have been conducted on a 6% solution of polystyrene (1.86x106 molecular weight) in dioctyl phthalate. Birefringence is used to measure the extent of segmental orientation, whereas the dichroism is sensitive to orientation and deformation of concentration fluctuations associated with the process of flow-induced phase separation. The results indicate that these fluctuations grow predominately along the neutral (or vorticity axis) of a simple shear flow. At higher rates of shear, orientation in the flow direction is favored. The transition in orientation direction is accompanied by time-dependent behavior in the optical properties of the solution during shear and the onset of shear thickening of the viscosity and the first normal stress difference coefficient.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Rheologica acta 33 (1994), S. 317-321 
    ISSN: 1435-1528
    Keywords: Rheo-optics ; birefringence ; multiple-order retardation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Physics
    Notes: Abstract An improved procedure is proposed to solve the problem of measuring strong birefringence on flowing samples which have a retardation δ larger than π/2 The procedure can be applied to devices which are based on the modulation of the polarization vector with a high-speed rotating half-wave plate. It uses two optical configurations which have different responses to the retardation. By combining the information obtained from the two configurations, one can easily and accurately determine the actual retardation of the sample, irrespective of the quadrant in which the measured retardation is located, provided the sample is isotropic. This technique can also overcome the problem of large errors occurring in the vicinity of δ = (2m+1)π/2 due to the limited sensitivity around these values of δ. The use of the technique is illustrated with measurements on an isotropic solution of poly(benzyl glutamate) in m-cresol, which is strongly birefringent during shear flow.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...