Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Pharmaceutical research 16 (1999), S. 1602-1607 
    ISSN: 1573-904X
    Keywords: in vitro percutaneous absorption ; octyl methoxycinnamate ; benzophenone-3 ; sunscreens ; retention inside stratum corneum
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Abstract Purpose. The objectives of this study were to develop an in vitro model for studying sunscreen permeation in skin, and evaluate the influence of formulation differences. Methods. The sunscreens studied were two of the most widely used agents, octyl methoxycinnamate (OMC) and benzophenone-3. Preparations containing radiolabeled actives were applied to micro-Yucatan pig skin dermatomed to a thickness of 250−300 μm as a finite dose in a flow-through diffusion system. At the end of each experiment the amounts removed by washing, retained inside stratum corneum (SC) and penetrated into receptor and viable skin were determined. Results. The two sunscreens reached a peak level in SC within an hour. Benzophenone-3 penetrated skin to a greater extent than OMC. The opposite was true when comparisons of SC retention were made. The ratio of retained to penetrated amount of sunscreens from a hydroalcoholic formulation at the end of 10 hours was higher when the sunscreens were present together than alone. Conclusions. Despite the highly lipophilic nature of sunscreens, particularly OMC, SC is the rate limiting skin layer for penetration. Penetration and SC retention were formulation dependent. The ratio of SC content to the amount penetrated is a useful tool for evaluating sunscreen permeation.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Electroanalysis 9 (1997), S. 478-480 
    ISSN: 1040-0397
    Keywords: Ion-selective electrode ; Pentathia crown ether ; Mercury(II) ; Membrane sensor ; Neutral carrier ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Poly(vinyl chloride) (PVC)-based membrane of pentathia-15-crown-5 exhibits good potentiometric response for Hg2+ over a wide concentration range (2.51 × 10-5 to 1.00 × 10-1 mol dm-3) with a slope of 32.1 mV per decade of Hg2+ concentration. The response time of the sensor is as fast as 20 s. The electrode has been used for a period of six weeks and exhibits fairly good discriminating ability towards Hg2+ in comparison to alkali, alkaline and some heavy metal ions. The electrode can be used in the pH range from 2.7 to 5.0.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...